6-20 489 Generator Management Relay
GE Power Management
6.3 MEMORY MAP 6 COMMUNICATIONS
6
1242 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
1243 GENERAL INPUT B TRIP DELAY 1 to 50000 1 s F2 50
DIGITAL INPUTS / GENERAL INPUT C
1250 ASSIGN DIGITAL INPUT 0 to 7 1 F210 0
1251 ASSERTED DIGITAL INPUT STATE 0 to 1 1 F131 0
1252 INPUT NAME 0 to 12 1 F22 _
1258 BLOCK INPUT FROM ONLINE 0 to 5000 1 s F1 0
1259 GENERAL INPUT C CONTROL 0 to 1 1 F105 0
125A PULSED CONTROL RELAY DWELL TIME 0 to 250 1 s F2 0
125B ASSIGN CONTROL RELAYS (1-5) 0 to 4 1 F50 0
125C GENERAL INPUT C CONTROL EVENTS 0 to 1 1 F105 0
125D GENERAL INPUT C ALARM 0 to 2 1 F115 0
125E ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
125F GENERAL INPUT C ALARM DELAY 1 to 50000 1 s F2 50
1260 GENERAL INPUT C ALARM EVENTS 0 to 1 1 F105 0
1261 GENERAL INPUT C TRIP 0 to 2 1 F115 0
1262 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
1263 GENERAL INPUT C TRIP DELAY 1 to 50000 1 s F2 50
DIGITAL INPUTS / GENERAL INPUT D
1270 ASSIGN DIGITAL INPUT 0 to 7 1 F210 0
1271 ASSERTED DIGITAL INPUT STATE 0 to 1 1 F131 0
1272 INPUT NAME 0 to 12 1 F22 _
1278 BLOCK INPUT FROM ONLINE 0 to 5000 1 s F1 0
1279 GENERAL INPUT D CONTROL 0 to 1 1 F105 0
127A PULSED CONTROL RELAY DWELL TIME 0 to 250 1 s F2 0
127B ASSIGN CONTROL RELAYS (1-5) 0 to 4 1 F50 0
127C GENERAL INPUT D CONTROL EVENTS 0 to 1 1 F105 0
127D GENERAL INPUT D ALARM 0 to 2 1 F115 0
127E ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
127F GENERAL INPUT D ALARM DELAY 1 to 50000 1 s F2 50
1280 GENERAL INPUT D ALARM EVENTS 0 to 1 1 F105 0
1281 GENERAL INPUT D TRIP 0 to 2 1 F115 0
1282 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
1283 GENERAL INPUT D TRIP DELAY 1 to 50000 1 s F2 50
DIGITAL INPUTS / GENERAL INPUT E
1290 ASSIGN DIGITAL INPUT 0 to 7 1 F210 0
1291 ASSERTED DIGITAL INPUT STATE 0 to 1 1 F131 0
1292 INPUT NAME 0 to 12 1 F22 _
1298 BLOCK INPUT FROM ONLINE 0 to 5000 1 s F1 0
1299 GENERAL INPUT E CONTROL 0 to 1 1 F105 0
129A PULSED CONTROL RELAY DWELL TIME 0 to 250 1 s F2 0
129B ASSIGN CONTROL RELAYS (1-5) 0 to 4 1 F50 0
129C GENERAL INPUT E CONTROL EVENTS 0 to 1 1 F105 0
129D GENERAL INPUT E ALARM 0 to 2 1 F115 0
129E ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
129F GENERAL INPUT E ALARM DELAY 1 to 50000 1 s F2 50
12A0 GENERAL INPUT E ALARM EVENTS 0 to 1 1 F105 0
12A1 GENERAL INPUT E TRIP 0 to 2 1 F115 0
12A2 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
12A3 GENERAL INPUT E TRIP DELAY 1 to 50000 1 s F2 50
DIGITAL INPUTS / GENERAL INPUT F
12B0 ASSIGN DIGITAL INPUT 0 to 7 1 F210 0
12B1 ASSERTED DIGITAL INPUT STATE 0 to 1 1 F131 0
Table 6–1: 489 MEMORY MAP (Sheet 10 of 29)
ADDR NAME RANGE STEP UNITS FORMAT DEFAULT
1, 2, 3 See Table footnotes on page 6–39