Appendix A: System Configuration Worksheets 56
08 Special Intrusion Special belongings, such as gun cabinets
and wall safes.
Police Instant
1, 2, 3
09 Special Intrusion Special belongings, such as gun cabinets
and wall safes.
Police Standard
1, 2, 3
10 Entry/Exit Delay Entry and exit doors that require a standard
delay time. #
Police Standard
2, 3
11 Entry/Exit Delay Garage doors and entrances that require an
extended delay time. * #
Police Extended
2, 3
12 Entry/Exit Delay Driveway gates and entrances that require a
twice extended delay time. * #
Police Twice
Extended
2, 3
13 Instant Perimeter Exterior doors and windows. # Police Instant
2, 3
14 Instant Interior Interior doors. # Police Follower
2, 3
15 Instant Interior Interior PIR motion sensors. * # Police Follower
2, 3
16 Instant Interior Interior doors. # Police Follower
3
17 Instant Interior PIR motion sensors. * # Police Follower
3
18 Instant Interior PIR motion sensors subject to false alarms. *
#
Police Follower
3
19 Delayed Interior Interior doors that initiate a delay before
going into alarm. * #
Police Standard
3
20 Delayed Interior PIR motion sensors that initiate a delay
before going into alarm. * #
Police Standard
3
21 Local Instant Interior 24-hour local alarm zone protecting anything
that opens and closes.
Police Instant
1, 2, 3
22 Local Delayed Interior Same as group 21, plus activation initiates a
delay before going into alarm.
Police Standard
1, 2, 3
23 Local Instant Auxiliary 24-hour local alarm zone protecting anything
that opens and closes. ‡
Auxiliary Instant
1, 2, 3
24 Local Instant Auxiliary 24-hour local alarm zone protecting anything
that opens and closes. Sirens shut off at
restoral. *
Auxiliary Instant
1, 2, 3
25 Local Special Chime Notify the user when a door is opened.
Sounds emit from a local annunciator. *
Special
Chime
Instant
1, 2, 3
26 Fire 24-hour fire, rate-of-rise heat, and smoke
sensors. §
Fire Instant
1, 2, 3
27 Output Module Hardwire Output Module (HOM) lamp control
or other customer feature. ‡
Silent Instant
1, 2, 3
28 Output Module HOM, PIR motion sensor, sound sensor, or
pressure mat. ‡
Silent Instant
1, 2, 3
29 Auxiliary Freeze sensor. Auxiliary Instant
1, 2, 3
32 Output Module HOM, PIR motion sensor, sound sensor, or
pressure mat. ‡
Silent Instant 1, 2, 3
34 Gas Carbon monoxide (CO) Gas Detectors ‡ Auxiliary Instant
1, 2, 3
35 Local Instant Police
(Day Zone)
Local alarm in levels 1 and 2.
Reports to CS in level 3.
Police Instant
(level
3
only)
1, 2, 3
Table A3: Sensor Group Characteristics (Continued)
No. Name Application Alarm Delay
Restoral
Supervisory
CS Report
Chime
Active
Levels

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE 60-806-95R-16Z - Security Concord Express System Control Panel and is the answer not in the manual?

GE 60-806-95R-16Z - Security Concord Express System Control Panel Specifications

General IconGeneral
BrandGE
Model60-806-95R-16Z - Security Concord Express System Control Panel
CategorySecurity System
LanguageEnglish

Related product manuals