850-D Feeder Protection System
(Standard: English, High Voltage Power Supply, Graphical Control Panel)
Application D | | | | ||||||||||||||||| Distribution Feeder
Phase Currents - Slot J P1 | | | | | | | | | | | | | | | | | | | | 1A three-phase current inputs (J1) + 4 voltage inputs (J2)
P5 | | | | | | | | | | | | | | | | | | | | 5A three-phase current inputs (J1) + 4 voltage inputs (J2)
Phase Currents - Slot K NN | | ||||||||||||||||| No phase current inputs (Slot K)
P1||||||||||||||||||| 1A three phase current inputs (K1) with 4 voltage inputs(K2)
P5||||||||||||||||||| 5A three phase current inputs (K1) with 4 voltage inputs (K2)
Ground Currents G1 | | | | | | | | | | | | | | | | | | 1A ground input
G5 | | | | | | | | | | | | | | | | | | 5A ground input
S1 | | | | | | | | | | | | | | | | | | 1A ground + 1A sensitive ground input
S5 | | | | | | | | | | | | | | | | | | 5A ground + 5A sensitive ground input
D1 | | | | | | | | | | | | | | | | | | 1A ground + 1A polarizing current input
D5 | | | | | | | | | | | | | | | | | | 5A ground + 5A polarizing current input
Power Supply L ||||||||||||||||| 24 to 48 V DC
H||||||||||||||||| 110 to 250 V DC/110 to 230 V AC
Slot B (LV I/O) N | | | | | | | | | | | | | | | | None
R | | | | | | | | | | | | | | | | 6 x RTDs (Pt100, Ni100, Ni120)
S | | | | | | | | | | | | | | | | 6 x RTDs (Pt100, Ni100, Ni120, Cu10)
C | | | | | | | | | | | | | | | | 15 Digital Inputs
Slot C (LV I/O) N ||||||||||||||| None
R||||||||||||||| 6 x RTDs (Pt100, Ni100, Ni120)
S||||||||||||||| 6 x RTDs (Pt100, Ni100, Ni120, Cu10)
C||||||||||||||| 15 Digital Inputs
Slot F (HV I/O) A | | | | | | | | | | | | | | 2 Form A (Vmon), 3 Form C, 7 Digital Inputs (Int/Ext Supply)
M | | | | | | | | | | | | | | 4 SSR (HSHB), 1 Critical Failsafe Relay, 7 Digital Inputs (Int/Ext supply)
Slot G (HV I/O) N ||||||||||||| None
A||||||||||||| 2 Form A, 3 Form C, 7 Digital Inputs (Int/Ext Supply)
B||||||||||||| 10 Digital Inputs, 9 Form A
D||||||||||||| 8 Double Pole Outputs
K||||||||||||| 10 Digital Inputs, 5 Form A, 1 Form C
L||||||||||||| 7 DcmA O/P, 4 DcmA I/P, 1 RTD
M||||||||||||| 4 SSR (HSHB), 1 Form C Relay, 7 Digital Inputs (Int/Ext supply)
Slot H (HV I/O) N | | | | | | | | | | | | None
A | | | | | | | | | | | | 2 Form A, 3 Form C, 7 Digital Inputs (Int/Ext supply)
B | | | | | | | | | | | | 10 Digital Inputs, 9 Form A
D | | | | | | | | | | | | 8 Double Pole Outputs
F | | | | | | | | | | | | 10 Digital Inputs, 4 Arc flash inputs
K | | | | | | | | | | | | 10 Digital Inputs, 5 Form A, 1 Form C
M | | | | | | | | | | | | 4 SSR (HSHB), 1 Form C Relay, 7 Digital Inputs (Int/Ext supply)
Faceplate M | | ||||||||| Basic: Membrane Keypad with 3 Pushbuttons
G||||||||||| Standard: Rugged Keypad 3 Pushbuttons
A||||||||||| Advanced: Membrane Front Panel with 10 Pushbuttons
Current Protection D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard (850-D): 37(3), 50P (4/CT bank), 50N (4/CT bank), 50G (4/CT bank), 51P(4),
51N(4), 51G(2/CT bank), 50SG(4/CT bank), 50_2(4/CT bank), 51SG(2/CT bank), 51_2
(2/CT bank), RGF(3), SOTF (3/Bkr), 67P(4), 67N(4), 67G (1/CT bank), 67SG (1/CT bank),
67_2 (1/CT bank), 49(2), Load Encroachment (1/CT bank), Broken Conductor (3)
Voltage Monitoring and Protection S
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard (850-D): 27P (4/VT bank), 27X (2/VT bank), 59P(4), 59N(4), 59X (2/VT bank,
81O (6/VT bank), 81U (6/VT bank)
P
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Advanced (850-D): Standard + 25 (1/CT bank), 27T(4), 27Q(3/Bkr), 32(4), 32N(4), 55(4),
59_2 (2/VT banks), 81R (6/VT bank), Fast U/F (8), Neutral Admittance (3)
Control
T
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Advanced HMI (850-D): Setpoint Group Control, Virtual Inputs, Trip Bus(6), Breaker
Control (1/Bkr), VTFF (1/VT bank), FlexLogic, CLP (1/Bkr), 50BF (2/CT bank), Pole
Discordance(3), Autoreclose (1/Bkr), CT Supervision(3), Tab PBs, Annunciator Panel,
Configurable SLDs with Bay Control
Monitoring B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Basic: Breakers Coil Monitoring (1/Bkr), Breaker Arcing (1/Bkr), THD, Current Demand
(1/CT bank), Digital Counters (16), Data Logger
C||||||| Standard: Basic + Advanced Breaker Health (1/Bkr)
A||||||| Advanced: Standard + Harmonic Detection (6) + TEFD (1/Bkr)
Communications
1
1. Communications options 2A and 2E have been discontinued.
S E
|
|
|
|
|
|
|
|
|
|
Standard: Front USB, 1 x Rear RS485: Modbus RTU, DNP3.0, IEC60870-5-103 + 1 x
Ethernet (Modbus TCP, DNP)
1 E
|
|
|
|
|
|
|
|
|
|
Advanced: Front USB, 1 x Rear RS485 + 2 x Ethernet Fiber, MODBUS RTU/TCP,
DNP3.0, IEC 60870-5-103/104, 1588, SNTP, OPC-UA
1 P | | | | | Advanced + PRP
3 A | | | | | Advanced + Extended IEC 61850
3 E | | | | | Advanced + PRP + Extended IEC 61850
Advanced Communications Connector N | | | | None
S|||| ST, Multi-mode 1310 nm
C| | | | RJ45, Copper 10/100 M
Wireless Communication N | | | None
W | | | WiFi 802.11
Security B| | Basic
A| | Advanced: CyberSentry Level 1
Future Option N N Not Available