Concord 4 Series Security Systems 57
3. The touchpad displays “REGULAR USER CODES” or “REG CODES.” Press B until the
display reads “SYSTEM MASTER CODE” or “SYS MASTER,” then press
#.
4. Replace the existing code with the new 4 digit System Master Code then press
#.
5. Press
* + 00 + # to exit the programming menus.
Using Programming Shortcuts
A programming shortcut is a number that “jumps” you to a particular spot in the programming
menus.
A series of shortcut numbers takes you directly to the feature or code you want to change.
1. Enter User Programming.
Local Phone # + 9 + CODE
Remote Phone Access Dial the phone number + # + CODE + # + 9 + CODE
Touchpad 9 + CODE
2. Enter a programming command sequence.
Time * + 020 + TTTT + #
Date * + 021 + DDMMYY + #
Regular User Codes Concord 4 Concord Express V4
User 00: * + 0300000 + NNNN + # [* + 030000 + NNNN + #]
User 01: * + 0300010 + NNNN + # [* + 030001 + NNNN + #]
User 02: * + 0300020 + NNNN + # [* + 030002 + NNNN + #]
(continues up to User 229) (continues up to User 15)
User 229: * + 0302290 + NNNN + #
If using alphanumeric or fixed display touchpads, use A and B to scroll
through the code attributes and change them as required.
Partition Master Codes
(Concord 4 systems only)
Partition 1:* + 0310 + NNNN + #
Partition 2:* + 0311 + NNNN + #
Partition 3:* + 0312 + NNNN + #
Partition 4:* + 0313 + NNNN + #
Partition 5:* + 0314 + NNNN + #
Partition 6:* + 0315 + NNNN + #
System Master Code * + 0320 + NNNN + #
Direct Bypassing Attribute * + 030NNN1 + 1(off) or 2(on) + # (nnn = user no.)
* + 030NN1 + 1(off) or 2(on) + # (Concord Express V4)
Remote Access Attribute * + 030NNN2 + 1(off) or 2(on) + # (nnn = user no.)
* + 030NN2 + 1(off) or 2(on) + # (Concord Express V4)
System Test Attribute * + 030NNN3 + 1(off) or 2(on) + # (nnn = user no.)
* + 030NN3 + 1(off) or 2(on) + # (Concord Express V4)
Latchkey Report Attribute * + 030NNN4 + 1(off) or 2(on) + # (nnn = user no.)
* + 030NN4 + 1(off) or 2(on) + # (Concord Express V4)
Partition Assign Attribute
(Concord 4 systems only)
* + 030NNN5 + desired partitions 1-6 + # (nnn = user no.)
Downloading * + 041 + 1(off) or 2(on) + #
Touchpad Brightness * + 043 + 0 through 3 + #
Volume * + 044 + 0 through 7 + #
Voice Chime * + 045 + 1(off) or 2(on) + #

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96