*(,QWHUORJL[
User Instructions
466-2060 Rev A
March 2003
Concord Ultra
Part Number:
60-960-95
S t a t u s
F e a t u r e s
p r e s s b o t h
L i g h t s
S y s t e m
A w a y
P a g e r
O f f
N o D e l a y
p r e s s b o t h
p r e s s b o t h
T e s t S y s t e m W e e k l y
S i l e n t
S t a y
D
*
7
0 #
8
B
A
4
1
5
6
2
3
B y p a s s
M e n u
C
9
P r o g r a m U s e r S e t t i n g s
p r e s s 0 - 9 f o r o t h e r e n t r i e s .
P r e s s 1 f o r O F F ; p r e s s 2 f o r O N ;
P r e s s # t o s e l e c t o p t i o n o r a c c e p t e n t r y .
0 6
0 7
0 5
0 4
1 3
1 4
1 2
1 1
A r m t o S T A Y
Q u i c k G u i d e
D i s a r m S y s t e m / C a n c e l A l a r m
i f d e s i r e d .
2
0 1
0 2
0 3
3
1
0 8
0 9
1 0
P r e s s t o d e s e l e c t o p t i o n o r c a n c e l e n t r y .
C l o s e a l l p r o t e c t e d d o o r s a n d w i n d o w s .
P r e s s 3 + C O D E .
E x i t p r e m i s e s t h r o u g h d e l a y d o o r .
2
3
1
P r e s s 2 + C O D E .
C l o s e a l l p r o t e c t e d d o o r s a n d w i n d o w s .
P r e s s 4 t o a r m d e l a y d o o r s i n s t a n t l y ,
A r m t o A W A Y
Z o n e / S e n s o r N u m b e r
P r e s s 1 + C O D E .
2
1
P r e s s A o r B t o s c r o l l t h r o u g h m e n u s .
M a k e s u r e s y s t e m i s d i s a r m e d .
2
1
P r e s s 7 + 1 t o t u r n C H I M E o n o r o f f .
M a k e s u r e s y s t e m i s d i s a r m e d .
2
1
T u r n C H I M E O n / O f f
P r e s s B Y P A S S + C O D E + S e n s o r N o .
A r m s y s t e m t o d e s i r e d l e v e l .
B y p a s s S e n s o r s
S y s t e m i s O K
S t a t u s
F e a t u r e s
p r e s s b o t h
L i g h t s
S y s t e m
A w a y
P a g e r
O f f
N o D e l a y
p r e s s b o t h
p r e s s b o t h
T e s t S y s t e m W e e k l y
S i l e n t
S t a y
D
*
7
0 #
8
B
A
4
1
5
6
2
3
B y p a s s
M e n u
C
9
A r m e d
R e a d y
ZZZ*(,QWHUORJL[FRP

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the GE Concord Ultra and is the answer not in the manual?

GE Concord Ultra Specifications

General IconGeneral
Partitions2
User CodesUp to 48
CompatibilityGE/Interlogix Wireless Sensors
Power Supply16.5VAC, 25VA transformer
Battery LifeUp to 24 hours

Summary

Notices

FCC Part 15 and ACTA Part 68 Compliance

User compliance and telephone connection regulations.

Commands at a Glance

System Arming and Disarming Commands

Quick reference for arming/disarming the system.

Alarm and Sensor Control Commands

Commands for initiating alarms and managing sensors.

System Status and Feature Control Commands

Commands for checking status and controlling features like lights and chime.

Getting to Know Your Security System

Overview of System Components

Introduces the main parts of the security system.

Communicating with the Panel

Explains how the system communicates with the user.

Preventing Accidental Alarms

Cancelling and Preventing Accidental Alarms

Procedures and guidelines to avoid false alarms.

Basic System Operations

Arming Your System Levels

Details on arming levels and keychain operation.

Quick Arm, Quick Exit, and Chime Features

Features for efficient operation and audio alerts.

Exit and Entry Delay Times

Delay Time Examples and Options

Illustrative examples and extended/no delay options.

Auto STAY Arming Feature

Bypassing Sensors Directly

Method to bypass specific sensors when system is armed.

Bypassing Sensors Indirectly

Basic Light and Output Control

Controlling system lights and outputs.

Checking the Status of Your System

Short and Full System Status Checks

How to perform brief and detailed status checks.

Panic Alarms

Fire, Police, and Auxiliary Panic Alarms

Types, activation, and lighting during panic alarms.

Access Codes

Programming and Integrity of Access Codes

Rules for setting and securing codes.

User Code Privileges and Management

Master, partition, and regular user code privileges and changes.

Assigning Code Attributes

Bypassing, Remote Access, and Partition Jump Attributes

Attributes for sensor bypass, phone access, and partition navigation.

System Test and Latchkey Report Attributes

Attributes for testing and reporting specific events.

Setting the Time and Date

System Time and Date Configuration

Steps for setting system time and date.

Adjusting System Sounds and Touchpad Brightness

Silent Arming Features

Options for silent system arming.

Touchpad Beep and Voice Volume Adjustments

Customizing beep tones and voice prompt volume.

Touchpad Display Brightness and Wireless Siren Volume

Adjusting display illumination and siren volume.

Using the Energy Saver Feature

Energy Saver Temperature Settings

Configuring high and low temperature points.

Notification by Pager

Pager Message Content and Codes

Understanding codes and numbers in pager messages.

Creating Time Schedules

Time Schedule Options and Rollover

Scheduling consecutive days and rollover times.

Advanced Light Control

Controlling Lights by Schedule and Sensor

Linking lights to schedules and sensors.

Controlling Outputs by Time Schedule

Scheduled Arming

Opening and Closing Reports

Latchkey Paging

Paging notifications for specific user activity.

Notify by Exception

Alerts for events outside normal schedules.

The No Activity Feature

Using the Panel Download Feature

Using a Partitioned System

Global and Partition-Specific Settings

Differentiating system-wide vs. partition settings.

Jumping Partitions

Navigating between system partitions.

System Information

Viewing Event Buffer

Accessing and interpreting system event logs.

Using a Touchtone Phone to Operate Your System

Phone Command Prefix and Access Methods

How to initiate phone commands.

Remote System Access

Accessing the system from off-site.

Touchtone Phone System Operation

Phone Control Commands

List of commands executable via phone.

Sending Panic Alarms via Phone

Using phone to trigger panic alarms.

Phone Operation FAQs

Answers to common phone control questions.

Testing the System

Automatic and Manual Test Features

Overview of system testing modes.

Sensor Test Procedures

Detailed steps for testing sensors.

Phone Communication Test

Verifying system connection to the monitoring station.

Troubleshooting

Trouble Beeps and Messages

Interpreting system alerts.

Common Questions and Answers

Addressing frequent user queries.

Phone and Siren Issues

Specific troubleshooting for phone and siren problems.

Appendix A: User Sheets

System Sensors Configuration

Recording sensor information.

User Codes Configuration

Recording user access codes.

Touchpad and Keychain Information

Details on touchpads and keychains.

Accidental Alarms and Dialer Abort

Handling accidental alarms and abort features.

Doors and Delay Time Settings

Configuration of entry and exit delays.

System Features

Quick Arm, Quick Exit, and Extension Features

Descriptions of specific arming/exiting features.

Auto STAY Arming and Keyswitch Arming

Descriptions of additional arming features.

Power Failure and No Activity Monitoring

Resetting the Smoke Detector

System Information and Paging Configuration

Lights Configuration

Partition 1 and Partition 2 Light Settings

Light control specific to partitions.

Outputs Configuration

Energy Saver Configuration

Alarm Sounds and Status Beeps

Alarm Types and Beep Codes

Understanding different alarm sounds and beeps.

Appendix B: Planning for Emergencies

Emergency Planning Guidelines

General advice for emergency situations.

Floor Plan Creation

Instructions for drawing a floor plan.

Alarm System Limitations

System Service and Contact Information

Appendix C: Programming Your System

Programming Methods Overview

Explains menu-driven and shortcut programming.

Using Programming Menus

Step-by-step guide for menu navigation.

Examples of Menu Programming

Practical demonstrations of programming tasks.

User Code Management

Procedures for changing, assigning, and erasing user codes.

Partition and Master Code Management

How to manage partition and master codes.

Assigning Code Attributes

Defining specific user permissions.

Using Programming Shortcuts

Related product manuals