Output 3 Attaching schedules for Output 3 operation:
Sched 0: * + 065200 + 1(off) or 2(on) + #
Sched 1: * + 065201 + 1(off) or 2(on) + #
(Continues through Schedule 15)
Sched 15: * + 065215 + 1(off) or 2(on) + #
Output 4 Attaching schedules for Output 4 operation:
Sched 0: * + 065300 + 1(off) or 2(on) + #
Sched 1: * + 065301 + 1(off) or 2(on) + #
(Continues through Schedule 15)
Sched 15: * + 065315 + 1(off) or 2(on) + #
Output 5 Attaching schedules for Output 5 operation:
Sched 0: * + 065400 + 1(off) or 2(on) + #
Sched 1: * + 065401 + 1(off) or 2(on) + #
(Continues through Schedule 15)
Sched 15: * + 065415 + 1(off) or 2(on) + #
Output 6 Attaching schedules for Output 6 operation:
Sched 0: * + 065500 + 1(off) or 2(on) + #
Sched 1: * + 065501 + 1(off) or 2(on) + #
(Continues through Schedule 15)
Sched 15: * + 065515 + 1(off) or 2(on) + #
Arm to AWAY Attaching schedules for Arming to AWAY operation:
Sched 0: * + 066000 + 1(off) or 2(on) + #
Sched 1: * + 066001 + 1(off) or 2(on) + #
(Continues through Schedule 15)
Sched 15: * + 066015 + 1(off) or 2(on) + #
Energy Saver Setpoints
Low: * + 070 + NN + #
High: * + 071 + NN + É
(enter temperature value in Fahrenheit)
Factory Code * + 010
System Number * + 011
System Level * + 012
Software Version * + 013
Attach Lights to Sensors Attaching schedules for Arming to AWAY operation:
Light 1: * + 080 + NN + # (nn = sensor no. to be attached)
Light 2: * + 081 + NN + # (nn = sensor no. to be attached)
(Continues through Light 9)
Light 9: * + 088 + NN + # (nn = sensor no. to be attached)
Exit * + 00 + #
2. Enter a programming command sequence. (continued)

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512