8.7 Appendix 7: Event log events
Event message Explanation
Alarm An alarm has been tripped.
Alarm Restore
See Alarm event message.
Autotest
An autotest message was sent to the central station.
B-Alarm A full alarm on a B zone type that is considered a burglary alarm.
Box Tamper
A box tamper.
Box Tamper
Restore
See Box Tamper event message.
Burglary
A burglary zone has been tripped.
Burglary Restore See Burglary event message.
Bypass
A zone is bypassed.
Bypass Restore
See Bypass event message.
Cancel The report to the central station has been cancelled. This occurs when a user enters
a code after an alarm.
CleanMe A smoke detector is dirty.
CleanMe Restore
See CleanMe event message.
Clock Set
A user set the date and time.
Close (arm) Closing (arm) by a specific user.
Code Entry
The lock of the access reader has been triggered.
The lock can be triggered by an accepted proximity card or by an Egress switch. An
Egress switch is a button that can be pressed by a user to open the lock of the door.
It can also be called Request-to-Exit (RTE). When the Code Entry option is
activated, the reader sends a log message to the control panel, indicating that the
lock has been triggered.
Data Lost
The panel has been unable to send alarm messages to the central station. The
panel tries to send these messages a number of times as specified in the FTC (Dial
attempts before Fail to Communicate). Any pending reportable events are lost.
Disarm from Alarm A user disarmed the panel during an alarm.
Duress
A duress code entered by a user. An alarm message is sent to the central station.
Early Open
A user disarmed the system before the open time specified in the panel schedules.
End Download The end of an up/download.
End Prog
End programming. The installer left programming mode.
End Walktest
See Walktest event message.