72
10 Technical Parameters
User Manual V1.0-2023-10-30
Technical Data
GEH15-
3U-10
GEH20-
3U-10
GEH25-
3U-10
GEH29�9-
3U-10
GEH30-
3U-10
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Switch
*7
Integrated
DC Surge Protection Type II
AC Surge Protection Type III
AFCI Integrated
Remote Shutdown Integrated
General Data
Operating Temperature Range
()
-35~+60
Relative Humidity 0~95%
Max. Operating Altitude (m) 4000
Cooling Method Smart Fan Cooling
Display LED, WLAN+APP
Communication with BMS RS485 / CAN
Communication with Meter RS485
Communication with Portal WiFi / 4G
Weight (kg) 48 48 54 54 54
Dimension W×H×D (mm) 520×660×220
Noise Emission (dB) <45 <45 <45 <60 <60
Topology Non-isolated
Self-consumption at Night (W)
*8
<15
Ingress Protection Rating IP66
DC Connector MC4
AC Connector OT
Environmental Category 4K4H
Pollution Degree III
Overvoltage Category DC II / AC III