71
10 Technical Parameters
User Manual V1.0-2023-10-30
Technical Data
GEH15-
3U-10
GEH20-
3U-10
GEH25-
3U-10
GEH29�9-
3U-10
GEH30-
3U-10
Max. Output Apparent Power
Without Grid (VA)
*6
15,000
(18,000
@60s ,
24,000
@3s)
20,000
(24,000
@60s ,
32,000
@3s)
25,000
(30,000
@60sec)
30,000
(36,000
@60sec)
30,000
(36,000
@60sec)
Max. Output Apparent Power
with Grid (VA)
15,000 20,000 25,000 29,900 30,000
Nominal Output Current (A) 22.7 30.3 37.9 45.5 45.5
Max. Output Current (A)
22.7 (27.3
@60s,
36.4 @3s)
30.3 (36.4
@60s,
48.5 @3s)
37.9 (45.5
@60s)
45.5 (54.5
@60s)
45.5 (54.5
@60s)
Max. Output Fault Current
(Peak and Duration) (A)
94
Inrush Current (Peak and
Duration) (A)
264@53us
Maximum Output Overcurrent
Protection (A)
94
Nominal Output Voltage (V) 380/400
Nominal Output Frequency (Hz) 50/60
Output THDv (@Linear Load) <3%
E󰀩ciency
Max. E󰀩ciency 98.0%
European E󰀩ciency 97.5%
Max. Battery to AC E󰀩ciency 97.5%
MPPT E󰀩ciency 99.9%
Protection
PV String Current Monitoring Integrated
PV Insulation Resistance
Detection
Integrated
Residual Current Monitoring Integrated
PV Reverse Polarity Protection Integrated
Battery Reverse Polarity
Protection
Integrated
Anti-islanding Protection Integrated