10
Electrical Specifi cations
Component Operating Voltage Resistance Wattage Frequency
Diverter Motor Motor - 120 VAC
Position Switch - 5 VDC
1.4 kΩ N/A N/A
Door Lock Solenoid 120 VAC 50 Ω N/A N/A
Drain Pump 120 VAC 14.8 Ω N/A N/A
Flow Meter 12 VDC N/A N/A N/A
Heater 120 VAC 14.6 Ω ~1000 N/A
Overnight Dry Fan 12 VDC N/A N/A N/A
Pressure Sensor 5 VDC N/A N/A See Chart * Below
Recirculation Pump 120 VAC 14.6 Ω N/A N/A
Stator 3 Phase DC 16.6 Ω per
phase
N/A N/A
Thermistor 5 VDC See Thermistor
Chart
N/A See Chart ** Below
Tub Lamp 3.1 VDC N/A N/A N/A
Water Valve 120 VAC 1 kΩ N/A N/A
Resistance Temperature
36.5 k 32 °F
14.7 k 68 °F
12.0 k 77 °F
9.8 k 86 °F
8.0 k 95 °F
6.6 k 104 °F
.5 k 257°F
Water Level Name Amount of
water in
basket
Frequency
Empty N/A 44.67 Hz
Steam Reset -0.4” 43.68 Hz
Steam Set 0” 43.45 Hz
Foam Reset .68 “ 43.02 Hz
Foam Set 1.47” 42.54 Hz
Main Reset 1.86” 42.30 Hz
Main Set 2.85” 41.71 Hz
Door Drain Reset 4.72” 40.57 Hz
Door Drain Set 5.47” 40.11 Hz
Overfl ow Set 10.56” 37.04 Hz
Frequency Chart * Thermistor Chart **