Faults A-11
Fault
Code
Hex
Name Description Repair Action
A Slow Fill (Flow
Meter)
Slow ll during ow
meter ll.
Check house water supply and proper water
pressure.
Check for kinked hoses.
Check hose and water valve screens.
• Check ow meter wiring.
• Replace ow meter.
Replace IMC board.
B Drain Pump Water remaining it tub. Check drain pump clean out.
Check installation instructions for proper
standpipe height.
Check pressure sensor frequency.
COver ow Condition Water level went above
the over ow level on 2
separate occasions.
Check for water valve sticking open.
Check pressure sensor frequency.
D Inverter Communi-
cation Timeout
The UI has not received
the inverter status
message in 10 seconds.
Reset control boards by unplugging the
washer for 30 seconds.
Check the wiring between the IMC and UI
boards.
If still no operation, replace IMC (Inverter
Machine Control).
E Door Open While the unit was
running the door was
detected as open.
Ensure proper loading (Unbalanced loads can
cause this).
Check for door closing properly or warped
door.
Check door lock and wiring.
F Door Unlocked While the unit was
running the door was
detected as unlocked.
Ensure proper loading (Unbalanced loads can
cause this).
Check for door closing properly or warped
door.
Check door lock and wiring.
10 Max Water Volume More than 13 gallons
of water entered tub.
Max Water Volume is
reset each time the unit
drains
• Check ow meter and ow meter wiring.
Check pressure sensor, pressure sensor
wiring and pressure sensor hose.
Replace pressure sensor.
• Replace ow meter.
Replace IMC board.
11 Door Lock Error Door fails to lock after
more than 3 attempts.
Check for door closing properly or warped
door.
Check for broken or deformed door latch.
Check door lock and wiring.