66
Drain Pump
Operating Voltage: 120 VAC
Resistance: 14.8 Ω
Drain Pump Location (Front View)
Recirculation Pump
Drain Pump
Drain pump operation is controlled by a relay on the 
IMC board. The drain pump will be energized any 
time the pressure sensor frequency reads above the 
overfl ow level.
Drain Pump Strip Circuit
IMC J701-4
D
To Neutral
IMC J101-2
Drain Pump
Switched L1
Drain Pump Tests
1. Enter service mode.
2. Run Test 12.
3. Press the Start key to begin the test.
4. The door locks and the cold water valve is turned 
on. The control will fi ll to the main water level, and 
then turn off  the valve.
Drain Pump Diagnostics
5. Check for current draw at IMC J701-4.
a. If current draw is detected and water is not 
draining, check for foreign material in pump 
and pump fi lter.
b. If no current draw is detected, go to step 2.
6. Check for 120 VAC between IMC J701-4 and IMC  
J101-2.
a.  If 120 VAC is not present replace the IMC 
board.
b.  If 120 VAC is present check wiring between 
IMC board and pump. If wiring is ok replace 
pump.
 Drain Pump Removal
1. Disconnect power to the unit.
2. Open the pump clean out and drain excess water.
3.  Remove the control panel. (See Control Panel 
Removal)
4.  Remove the front panel. (See Front Panel Re-
moval)
5. Remove the wire harnesses from the drain pump 
and recirculation pump (if present).
Drain Pump Harness
Recirc Pump Harness
6. Remove the right front top damper pin and push 
the damper aside.
7. Remove the drain pump hose.
8. Remove the recirculation pump hose (if present).
9. Remove the 5/16” sump hose clamp and remove 
Wash System