65
of the diverter motor connector as the motor is
rotating.
a. If voltage is switching between 5 VDC and 0
VDC and the diverter runs continuously, re-
place the IMC board.
b. If voltage is a constant 5 VDC or 0 VDC, re-
place the diverter assembly.
Diverter Motor Assembly Removal
1. Disconnect power to the unit.
2. Remove the control panel. (See Control Panel
Removal)
3. Disconnect the diverter motor harness.
4. Using a at blade screwdriver, pry up the diverter
linkage arm from the diverter motor assembly.
5. Remove the two 1/4” hex diverter motor screws
and lift motor assembly up.