The Thermistor is Located in the Bottom of the
Tub Assembly Next to the Drain Pump and is
Removed by Removing the 2 - 5/16” Hex Screws.
Bottom of Subwasher
Thermistor
Be sure to reconnect Yellow signal
wire onto the thermistor and the
Brown wire on the heater. This is
needed to sense continuity through
the water in the tub to allow the
heater to come on. As water fills the
tub the connection is made between
the outer casing of the thermistor and
the heater. This then is read at the
inverter board.
NOTE: Make sure the
rubber O-RING is in place
before reinstalling the new
thermistor.