[*]-[9]-[0] READING THE EVENT LOG
The NX-8 has a 512-event log which can be retrieved using a master code. This log contains a
listing of the last 512 events along with the date, time, and partition where each event
occurred.
1. Press [*]-[9]-[0] The LCD screen will prompt you for a code.
2. Enter [master code] The LCD screen will now show the most recent event.
3. To view the events from the latest to the oldest, press the ‘down’ scroll key.
4. To view the events from the oldest to the latest, press the ‘up’ scroll key.
5. The display contains the following information.
Open 75
9/25 17:57 P3*
User or zone ID
Indicates partition and *
indicates an event not reported
Event
Date (month/Day)
Time shown in
24 hour format
This screen shows an opening of partition 3 on September 25th at 5:27 p.m. by user 75. The
[*] shows that this event is not programmed for reporting to the central monitoring station.
[*]-[9]-[5] SET INCREMENTS (HOURS/DAYS) ELAPSED SINCE LAST AUTOTEST
1. Enter [*]-[9]-[5] The LCD screen will prompt for a code.
2. Enter [program code] The LCD will now display the elapsed time screen.
3. Enter [100's digit] -[10's digit]-[1's digit]-[#]
[*]-[9]-[7] SET SYSTEM TIME AND DATE
1. Enter [*]-[9]-[7] The LCD screen will prompt for a code.
2. Enter [master code] The date and time will be displayed, with the current
hour flashing.
3. Use the ‘up’ and ‘down’ scroll keys to select the proper hour.
4. Enter the [*] key to move to the minutes.
5. Repeat until you have set the entire date.
[*]-[9]-[8]
Pressing [*]-[9]-[8] while the system is disarmed will cause the control panel to perform a
callback for a download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [*]-[9]-[8], IF
ENABLED IN LOCATION 41 OF THE NX-8 CONTROL PANEL.
[*]-[9]-[9]
Pressing [*]-[9]-[9] while the system is disarmed will cause the control panel to seize the phone
line for a download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [*]-[9]-[9], IF
ENABLED IN LOCATION 41 OF THE NX-8 CONTROL PANEL.
NX-8-EUR Installation manual Page 22 02/07/06