LOCATION 58 - TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS (8 segments, numerical data)
Location 58 contains the event code for a zone “Tamper” with a 4+2 and 3+1 format. For a 4+2
format, the digit programmed in this location will be sent as the tens digit of the tamper event
code. The zone ID will always be reported as the ones digit of the zone number (e.g. zone 16 =
6, zone 45 = 5).
This location contains 8 segments. Any segment left as “0” will follow the segment 1 selection.
Segment 1
Partition 1 “Tamper Code”
Segment 2
Partition 2 “Tamper Code”
Segment 3
Partition 3 “Tamper Code”
Segment 4
Partition 4 “Tamper Code”
Segment 5
Partition 5 “Tamper Code”
Segment 6
Partition 6 “Tamper Code”
Segment 7
Partition 7 “Tamper Code”
Segment 8
Partition 8 “Tamper Code”
LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data)
Location 59 contains the event code for a zone “Trouble” with a 4+2 and 3+1 format. For the
4+2 format, the digit programmed in this location will be sent as the tens digit of the trouble
event code. The zone ID will always be reported as the ones digit of the zone number (e.g. zone
16 = 6, zone 45 = 5).
This location contains 8 segments. Any segment left as “0” will follow segment 1 selection.
Segment 1
Partition 1 “Trouble Code”
Segment 2
Partition 2 “Trouble Code”
Segment 3
Partition 3 “Trouble Code”
Segment 4
Partition 4 “Trouble Code”
Segment 5
Partition 5 “Trouble Code”
Segment 6
Partition 6 “Trouble Code”
Segment 7
Partition 7 “Trouble Code”
Segment 8
Partition 8 “Trouble Code”
LOCATION 60 - SENSOR LOW BATTERY COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments,
numerical data)
Location 60 contains the event code for a zone “Sensor Low Battery” for a 4+2 and 3+1
format. For a 4+2 format, the digit programmed in this location will be sent as the tens digit of
the sensor low battery event code. The zone ID will always be reported as the ones digit of the
zone number (e.g. zone 16 = 6, zone 45 = 5).
This location contains 8 segments. Any segment left as “0” will follow the Segment 1 selection.
NX-8-EUR Installation manual Page 63 02/07/06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-8-EUR and is the answer not in the manual?

GE NetworX NX-8-EUR Specifications

General IconGeneral
BrandGE
ModelNetworX NX-8-EUR
CategoryControl Panel
LanguageEnglish

Related product manuals