Segment 1
Partition 1 “Sensor Low battery Code”
Segment 2
Partition 2 “Sensor Low battery Code”
Segment 3
Partition 3 “Sensor Low battery Code”
Segment 4
Partition 4 “Sensor Low battery Code”
Segment 5
Partition 5 “Sensor Low battery Code”
Segment 6
Partition 6 “Sensor Low battery Code”
Segment 7
Partition 7 “Sensor Low battery Code”
Segment 8
Partition 8 “Sensor Low battery Code”
LOCATION 61 - SENSOR MISSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 61 contains the event code for a zone “Sensor-missing” for a 4+2 and 3+1 format. For
a 4+2 format, the digit programmed in this location will be sent as the tens digit of the sensor
missing event code. The zone ID will always be reported as the ones digit of the zone number
(e.g. zone 16 = 6, zone 45 = 5).
This location contains 8 segments. Any segment left as “0” will follow the Segment 1 selection.
Segment 1
Partition 1 “Sensor Missing Code”
Segment 2
Partition 2 “Sensor Missing Code”
Segment 3
Partition 3 “Sensor Missing Code”
Segment 4
Partition 4 “Sensor Missing Code”
Segment 5
Partition 5 “Sensor Missing Code”
Segment 6
Partition 6 “Sensor Missing Code”
Segment 7
Partition 7 “Sensor Missing Code”
Segment 8
Partition 8 “Sensor Missing Code”
LOCATION 62 - DURESS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data)
Location 62 contains the tens and ones digits that will be sent for a 4+2 and 3+1 format if the
duress code is enabled in location 44. Segment 1 contains the tens digit, and segment 2
contains the ones digit.
For a 3+1 format, only the segment 1 digit (tens) will be sent.
LOCATION 63 - KEYPAD AUXILIARY 1 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,
numerical data)
Location 63 contains the tens and ones digits that will be sent for a 4+2 and 3+1 format if the
keypad “Auxiliary 1” (FIRE) is enabled in the partition feature selection. Segment 1 contains the
tens digit; segment 2 contains the ones digit.
For a 3+1 format, only the segment 1 digit (tens) will be sent.
NX-8-EUR Installation manual Page 64 02/07/06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-8-EUR and is the answer not in the manual?

GE NetworX NX-8-EUR Specifications

General IconGeneral
BrandGE
ModelNetworX NX-8-EUR
CategoryControl Panel
LanguageEnglish

Related product manuals