Segment 7 (Circle Numbers To Program)
1 dial via GSM when phone line trouble (only when NX-7002 is used)
2 Exit Error limited to Entry/Exit delay 1
37 51
1-8
Reserved
38 52 SWINGER COUNTDOWN COUNT
0
KEYPAD SOUNDER CONTROL
Segment 1 (Circle Numbers To Program)
1 Keypad sounds for Telephone Line Cut when in the Armed state
2 Keypad sounds for Telephone Line Cut when in the Disarmed state
3 Keypad sounds upon AC Power Failure
4 Keypad sounds upon Low Battery Detection
5 Keypad sounds during Cross Zone Trip Time
6 Keypad sounds for Tamper Alarm
7 Keypad sounds for Emergency keys
39
52
8 Keypad sounds for Expander Trouble
SYSTEM TIMERS
Segment 1
Dynamic Battery Test duration (0-255 minutes)
0
Segment 2
AC Failure report delay (0-255 minutes)
60
Segment 3
Power Up Delay (0-60 seconds)
0
Segment 4
Siren Time (1-255 minutes)
3
Segment 5
Telephone Line Cut delay (0-255 seconds)
0
Segment 6
Cross Zone Time (0-255 minutes)
5
Segment 7
Chime Time in 50 mS increments (0-255)
5
Segment 8
Dialer delay (0-255 seconds)
0
Segment 9
Fire Alarm Verification Time (120-255 seconds)
0
Segment 10
Listen-In Time (0-255 seconds)
0
Segment 11
Zone monitor timer hours/days (0-255)
0
Segment 12
Auto arming warning timer (1-255 minutes)
1
Segment 13
Auto arming retry timer (1-255 minutes)
45
40 53
Segment 14
Programming timeout (1-255 minutes) (“0”=15 minutes)
0
USER CODE REQUIREMENTS
Segment 1 (Circle Numbers To Program)
1 Enables six digit code option. All arm/disarm/Go to program codes require six digits
2 Requires valid user code entry so that [*]-[9]-[8] and [*]-[9]-[9] functions can work
3 Enables Auto Cancel / Abort
4 Reserved
5 On: keypad shutdown mode
6 On: user authorization to enter program mode
7 On: codes 16 and 17 are guard codes
41
53
8 Reserved
NX-8-EUR Installation manual Page 91 02/07/06