12 NX-
320E Power Supply
LOCATION 1 PROGRAMMING SPECIAL FEATURES FOR OUTPUT A
(2 segments of feature selection data)
Segment 1 selects the following special conditions:
1 = "On" if output should time in minutes; "Off" if output times in seconds.
2 = "On" if output should latch until a code is entered; “Off” for timed.
3 = "On" if output should stop time when a code is entered.
4 = “On” for inverted output.
5 = “On” disables output during listen-in (only events 12-16).
6 = Reserved.
7 = Reserved.
8 = Reserved.
Segment 2 selects the following partitions:
1 = "On" if the event should activate when it occurs in Partition 1.
2 = "On" if the event should activate when it occurs in Partition 2.
3 = "On" if the event should activate when it occurs in Partition 3.
4 = "On" if the event should activate when it occurs in Partition 4.
5 = "On" if the event should activate when it occurs in Partition 5.
6 = "On" if the event should activate when it occurs in Partition 6.
7 = "On" if the event should activate when it occurs in Partition 7.
8 = "On" if the event should activate when it occurs in Partition 8.
LOCATION 2 PROGRAMMING THE EVENT & TIME FOR OUTPUT B
(2 segments of numerical data)
Segment 1 is used to program the particular event that will trigger Output B. Refer to Table XII:1 on page 11 for
the specific events that can be selected.
Segment 2 is used to select the amount of time an output will remain activated when an output triggers. If this
location is programmed as a zero, the output will follow the particular event.
LOCATION 3 PROGRAMMING SPECIAL FEATURES FOR OUTPUT B
(2 segments of feature selection data)
Segment 1 selects the following special conditions:
1 = "On" if output should time in minutes; "Off" if output times in seconds.
2 = "On" if output should latch until a code is entered; “Off” for timed.
3 = "On" if output should stop time when a code is entered.
4 = "On" for inverted output.
5 = “On” disables output during listen-in (only events 12-16).
6 = Reserved.
7 = Reserved.
8 = Reserved.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")