NX-1348E-ICON       - 14 - 
g
GE Interlogix
 
OTHER KEYPAD FUNCTIONS 
Setting the keypad tone 
Step 1  Press [r]-[0].  Keypad is now in the “Adjust Tone” mode.   
Step 2  Pressing the [•] key will make the keypad sounder go to higher tones, pressing the [–] key will make the 
keypad sounder go to lower tones.  
Step 3  When the desired tone is reached, press the [#] key to set this tone and exit from the “Adjust Tone” mode. 
 
Change partition (optional) 
Step 1  Press [r]-[1]. 
Step 2  Press a NUMBER key between 1 and 8 to change partitions momentarily.   
Step 3  If no other key is pressed, it will go back to its standard partition in ten seconds.  
Step 4  If another key is pressed, the system will remain in the new partition until no keys have been pressed for 60 
seconds. 
 
View alarm memory 
Step 1  Press [r]-[3].   The zone(s) that created the last alarm will be displayed along with the alarm icon flashing on 
the keypad.  
Step 2  The ALARM MEMORY feature will flash those zones that created alarms and will display steady those zones 
that were bypassed during the last alarm. 
 
Test function (optional) 
If programmed, this function will perform a battery test, communicator test, and/or a siren test. Alarms and reports will 
not
 be sent, unless a communicator test is performed at which time a test signal will be sent. 
 
Step 1  Press [r]-[4].  The test will be performed as programmed. 
Step 2  If the siren test is performed, enter a user code to silence the siren. 
 
Reset function 
This function is used to reset Smoke Detectors and Zone Troubles.  Your system must be Disarmed to use the Reset 
function. 
 
Step 1  Press [r]-[7].   Resets have now been performed. 
Step 2  If the keypad begins beeping, the reset did not execute properly. Enter your code to silence the keypad. Wait a 
few minutes and repeat step 2 to attempt another reset. If the keypad still beeps after repeated attempts, please 
contact your installer.