LCD KEYPAD 13
DISPLAY DESCRIPTION
Open Open - Reports user number, date, time and partition of opening.
Close Close - Reports user number, date, time and partition of closing.
Exit Err Exit Error - Entry/Exit zone was faulted at the instant the exit delay expired.
Rec Close Recent Close - An alarm occurred within 5 minutes after the control was armed.
Autotest Auto Test - Sending a communicator test at a specified interval.
Start Prog Start Programming - Local programming is started.
End Prog End Programming - Local programming is ended.
Start Dnld Start Download - Download session is started.
End Dnld End Download - Download session is ended.
Cancel Cancel - System is disarmed; Cancel was initiated within 5 minutes of an alarm.
Gnd Flt Ground Fault - A short to ground has been detected.
Man Test Manual Test - Bell and/or communicator test while system is in disarmed condition.
Re-exit Re-Exit - The exit delay has been re-started without disarming the system.
Output Trip Output Trip - A trip has occurred on an expander auxiliary output.
Data Lost Data Lost - Communication of a signal has failed (log only event).
Walk-test Walk-Test - A zone “Walk-Test” mode has been activated.
End Test End Test - Test has been ended.
Cross-Trip Cross Trip - The first zone of a cross zone has been tripped (log only event).
Expansion
Event
Expansion Event - An expansion module has created an undefined event.
Partial Arm Partial Arm - Reports a closing in the stay mode.
Listen In Listen In - A listen in function has been activated.
Service Start Service Start - Technician is on site.
Service End Service End - Technician is off site.
Code Entry Code Entry - A code has been entered.
First Open First Open - Reports when the first partition is disarmed.
Last Close Last Close - Reports when the last partition is armed.
Sprnklr Sprinkler - Instant sprinkler supervisory report
Clock Set Clock Set - Clock has been reset.
RF Jammed RF Jammed - A wireless expansion module is jammed
CleanMe CleanMe - A smoke detector requires cleaning.
7b. SET ELAPSED TIME IN MINUTES SINCE LAST AUTOTEST
ACTION RESULT

Prompts for a code.
[program code]
Displays the elapsed time screen.
(example only)
[100's digit] [10's digit] [1's digit]
#
Saves and exits.