9 SCADA Communications
P50 Agile P253
P253/EN M/C
In the table below, the text shaded as indicates Subset Level 3 functionality (beyond Subset Level
2). Text shaded as indicates functionality beyond Subset Level 3.
OBJECT
REQUEST
(Library will parse)
RESPONSE
(Library will respond with)
Object
Number
Variation
Number
Description
Function
Codes(dec)
Qualifier
Codes (hex)
Function
Codes
(dec)
Qualifier
Codes (hex)
1
0
Binary Input
(Variation 0 is used to
request default
variation)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 28 (index)
1
1(default –
see note 1)
Binary Input
1 (read)
22
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index –
see note 2)
1
2
Binary Input with
Status
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index –
see note 2)
2
0
Binary Input Change
(Variation 0
is used to request
default variation)
1 (read)
06 (no range, or all)
07, 08 (limited qty)
2
1
Binary Input Change
without Time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
17, 28 (index)
2
2(default –
see note 1)
Binary Input Change
with Time
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129 (response)
17, 28 (index)
10
0
Binary Output Status
(Variation 0is used to
request default
variation)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 28 (index)
10
2(default –
see note 1)
Binary Output Status
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index –
see note 2)
12
1(default –
see note 1)
Control Relay Output
Block
3 (select)
4 (operate)
5(direct op)
6 (dir.op,noack)
00, 01 (start-stop)
07, 08 (limited qty)
17, 28 (index)
129 (response)
Echo of request

Table of Contents