Door Switch
Door Switch
The door switch is fastened to the front panel by 2
locking tabs (1 on each side). When the dryer door
is closed, the switch will complete the drum motor
circuit, allowing dryer operation. When the door is
open, the switch will open the drum motor circuit,
interrupting dryer operation. Opening the dryer door
will also cause the door switch to close the drum
light circuit, allowing the drum light to be energized.
Operation of the inlet control thermistor can be
checked by using service test mode t9. (See Service
Test Mode.)
Specifi c failures associated with the door switch can
initiate error code E6. (See Service Test Mode.)
Drum Light
Receptacle
Drum Light Receptacle
The drum light receptacle is attached to the inside of
the front panel with a single Phillips-head screw. It is
necessary to remove the front panel and drum slide
assembly to replace the drum light receptacle.
To replace the steam nozzle connector:
1. Remove the air duct assembly.
2. Press on the John Guest connector collar and
release the water line from the steam nozzle
connector.
3. Remove the 2 Phillips-head screws that attach
the nozzle housing to the air duct.
4. Pull the nozzle housing out from the air duct.
5. Remove the Phillips-head screw that attaches
the nozzle to the nozzle housing.
Steam Nozzle
Connector
John Guest
Connector
Collar
6. Pull the nozzle connector out of the housing.
Locking Tabs
Door Switch Front View