Chapter 12 Page no. 136 12-imgac.fm
GE Healthcare Senographe DS Acquisition System
Revision 1 Operator Manual 5307907-3-S-1EN
Image Acquisition Procedure
- Premium View. This is an image processing algorithm which increases the visibility of breast
structures. The main advantage is to provide a single breast image, where the contrast in the fatty
tissues is similar to the one obtained by setting WW (window width) and WL (window level) for
optimum visualization of fatty tissues, and the contrast in the fibro-glandular tissue is similar to the
one obtained by setting WW and WL for optimal visualization of fibro-glandular tissues. Premium
View algorithm also includes a Thickness Equalization algorithm to enhance the visibility of sub-
cutaneous tissues.
Under certain specific conditions (e.g. particular exposure techniques) the Premium View algo-
rithm cannot be applied.
Note:
Premium View is an image processing algorithm optimized for the structure of breast imag-
es.
- When imaging an object with thick or sharp borders (e.g., a phantom), one might see
an enhanced brightness at the border of the object. This enhancement is normal and is
not expected to affect correct phantom scoring.
Note:
When acquiring images with Spot paddle in Mag mode or in Contact mode, the Premium View al-
gorithm output may not be optimal. In this case, a satisfactory image display may be obtained by
adjusting window level and window width.
Auto-contrast. This improves image quality by optimizing the levels of brightness (window level) and
contrast (window width) in the image.
As soon as the selected algorithm has been applied, the processed image replaces the raw image on
the screen. The operator can select which of four levels of contrast should be applied (High, Low,
Standard, or User defined, selected in the Viewer Control Panel window).
For Premium View, there is no predefined user value, but User level can be set if the user saves the
image with modified levels.
FOR TRAINING PURPOSES ONLY!
NOTE: Once downloaded, this document is UNCONTROLLED, and therefore may not be the latest revision. Always confirm revision status against a validated source (ie CDL).

Table of Contents

Other manuals for GE Senographe DS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Senographe DS and is the answer not in the manual?

GE Senographe DS Specifications

General IconGeneral
BrandGE
ModelSenographe DS
CategoryMedical Equipment
LanguageEnglish

Related product manuals