GE Multilin T60 Transformer Protection System B-15
APPENDIX B B.4 MEMORY MAPPING
B
1E04 Source 1 Demand Ic 0 to 999999.999 A 0.001 F060 0
1E06 Source 1 Demand Watt 0 to 999999.999 W 0.001 F060 0
1E08 Source 1 Demand Var 0 to 999999.999 var 0.001 F060 0
1E0A Source 1 Demand Va 0 to 999999.999 VA 0.001 F060 0
1E0C Reserved (4 items) --- --- --- F001 0
1E10 ...Repeated for Source 2
1E20 ...Repeated for Source 3
1E30 ...Repeated for Source 4
1E40 ...Repeated for Source 5
1E50 ...Repeated for Source 6
Source Demand Peaks (Read Only Non-Volatile) (6 modules)
1E80 Source 1 Demand Ia Maximum 0 to 999999.999 A 0.001 F060 0
1E82 Source 1 Demand Ia Maximum Date 0 to 4294967295 --- 1 F050 0
1E84 Source 1 Demand Ib Maximum 0 to 999999.999 A 0.001 F060 0
1E86 Source 1 Demand Ib Maximum Date 0 to 4294967295 --- 1 F050 0
1E88 Source 1 Demand Ic Maximum 0 to 999999.999 A 0.001 F060 0
1E8A Source 1 Demand Ic Maximum Date 0 to 4294967295 --- 1 F050 0
1E8C Source 1 Demand Watt Maximum 0 to 999999.999 W 0.001 F060 0
1E8E Source 1 Demand Watt Maximum Date 0 to 4294967295 --- 1 F050 0
1E90 Source 1 Demand Var 0 to 999999.999 var 0.001 F060 0
1E92 Source 1 Demand Var Maximum Date 0 to 4294967295 --- 1 F050 0
1E94 Source 1 Demand Va Maximum 0 to 999999.999 VA 0.001 F060 0
1E96 Source 1 Demand Va Maximum Date 0 to 4294967295 --- 1 F050 0
1E98 Reserved (8 items) --- --- --- F001 0
1EA0 ...Repeated for Source 2
1EC0 ...Repeated for Source 3
1EE0 ...Repeated for Source 4
1F00 ...Repeated for Source 5
1F20 ...Repeated for Source 6
Breaker Flashover (Read/Write Setting) (2 modules)
21A6 Breaker Flashover 1 Function 0 to 1 --- 1 F102 0 (Disabled)
21A7 Breaker Flashover 1 Side 1 Source 0 to 5 --- 1 F167 0 (SRC 1)
21A8 Breaker Flashover 1 Side 2 Source 0 to 6 --- 1 F211 0 (None)
21A9 Breaker Flashover 1 Status Closed A 0 to 65535 --- 1 F300 0
21AA Breaker Flashover 1 Status Closed B 0 to 65535 --- 1 F300 0
21AB Breaker Flashover 1 Status Closed C 0 to 65535 --- 1 F300 0
21AC Breaker Flashover 1 Voltage Pickup Level 0 to 1.5 pu 0.001 F001 850
21AD Breaker Flashover 1 Voltage Difference Pickup Level 0 to 100000 V 1 F060 1000
21AF Breaker Flashover 1 Current Pickup Level 0 to 1.5 pu 0.001 F001 600
21B0 Breaker Flashover 1 Pickup Delay 0 to 65.535 s 0.001 F001 100
21B1 Breaker Flashover 1 Supervision Phase A 0 to 65535 --- 1 F300 0
21B2 Breaker Flashover 1 Supervision Phase B 0 to 65535 --- 1 F300 0
21B3 Breaker Flashover 1 Supervision Phase C 0 to 65535 --- 1 F300 0
21B4 Breaker Flashover 1 Block 0 to 65535 --- 1 F300 0
21B5 Breaker Flashover 1 Events 0 to 1 --- 1 F102 0 (Disabled)
21B6 Breaker Flashover 1 Target 0 to 2 --- 1 F109 0 (Self-Reset)
21B7 Reserved (4 items) --- --- --- F001 0
21BB ...Repeated for Breaker Flashover 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E0 Breaker 1 Arcing Current Amp Phase A 0 to 99999999 kA
2
-cyc 1 F060 0
21E2 Breaker 1 Arcing Current Amp Phase B 0 to 99999999 kA
2
-cyc 1 F060 0
21E4 Breaker 1 Arcing Current Amp Phase C 0 to 99999999 kA
2
-cyc 1 F060 0
21E6 Breaker 1 Operating Time Phase A 0 to 65535 ms 1 F001 0
21E7 Breaker 1 Operating Time Phase B 0 to 65535 ms 1 F001 0