EasyManua.ls Logo

GE UR T60 - Page 569

GE UR T60
724 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GE Multilin T60 Transformer Protection System B-31
APPENDIX B B.4 MEMORY MAPPING
B
Demand (Read/Write Command)
47D4 Demand Clear Record 0 to 1 --- 1 F126 0 (No)
FlexCurves A and B (Read/Write Settings)
4800 FlexCurve A (120 items) 0 to 65535 ms 1 F011 0
48F0 FlexCurve B (120 items) 0 to 65535 ms 1 F011 0
Modbus User Map (Read/Write Setting)
4A00 Modbus Address Settings for User Map (256 items) 0 to 65535 --- 1 F001 0
User Displays Settings (Read/Write Setting) (16 modules)
4C00 User-Definable Display 1 Top Line Text --- --- --- F202
4C0A User-Definable Display 1 Bottom Line Text --- --- --- F202
4C14 Modbus Addresses of Display 1 Items (5 items) 0 to 65535 --- 1 F001 0
4C19 Reserved (7 items) --- --- --- F001 0
4C20 ...Repeated for User-Definable Display 2
4C40 ...Repeated for User-Definable Display 3
4C60 ...Repeated for User-Definable Display 4
4C80 ...Repeated for User-Definable Display 5
4CA0 ...Repeated for User-Definable Display 6
4CC0 ...Repeated for User-Definable Display 7
4CE0 ...Repeated for User-Definable Display 8
4D00 ...Repeated for User-Definable Display 9
4D20 ...Repeated for User-Definable Display 10
4D40 ...Repeated for User-Definable Display 11
4D60 ...Repeated for User-Definable Display 12
4D80 ...Repeated for User-Definable Display 13
4DA0 ...Repeated for User-Definable Display 14
4DC0 ...Repeated for User-Definable Display 15
4DE0 ...Repeated for User-Definable Display 16
Field Unit Raw Data Actuals (Read Only) (8 modules)
4E00 Raw Field Data AC1 Mag 0 to 0.001 A 0.001 F003 0
4E02 Raw Field Data AC1 Angle 0 to 0.1 degree 0.1 F002 0
4E03 Raw Field Data AC2 Mag 0 to 0.001 A 0.001 F003 0
4E05 Raw Field Data AC2 Angle 0 to 0.1 degree 0.1 F002 0
4E06 Raw Field Data AC3 Mag 0 to 0.001 A 0.001 F003 0
4E08 Raw Field Data AC3 Angle 0 to 0.01 degree 0.1 F002 0
4E09 Raw Field Data AC4 Mag 0 to 0.001 A 0.001 F003 0
4E0B Raw Field Data AC4 Angle 0 to 0.01 degree 0.1 F002 0
4E0C Raw Field Data AC5 Mag 0 to 0.001 A/V 0.001 F003 0
4E0E Raw Field Data AC5 Angle 0 to 0.01 degree 0.1 F002 0
4E0F Raw Field Data AC6 Mag 0 to 0.001 A/V 0.001 F003 0
4E11 Raw Field Data AC6 Angle 0 to 0.01 degree 0.1 F002 0
4E12 Raw Field Data AC7 Mag 0 to 0.001 A/V 0.001 F003 0
4E14 Raw Field Data AC7 Angle 0 to 0.01 degree 0.1 F002 0
4E15 Raw Field Data AC8 Mag 0 to 0.001 A/V 0.001 F003 0
4E17 Raw Field Data AC8 Angle 0 to 0.01 degree 0.1 F002 0
4E18 Raw Field Data DC1 0 to 0.001 V 0.001 F002 0
4E19 Raw Field Data DC2 0 to 0.001 V 0.001 F002 0
4E1A Raw Field Data DC3 0 to 0.001 V 0.001 F002 0
4E1B Raw Field Data FCI States (2 items) 0 to 1 --- 1 F500 0
4E1D Raw Field Data SI States 0 to 1 --- 1 F500 0
4E1E Raw Field Data SI Test States 0 to 1 --- 1 F500 0
4E1F Raw Field Data Brick ADC Temperature 0 to 1 degree 1 F002 0
4E20 Raw Field Data Brick Transceiver Temperature 0 to 1 degree 1 F002 0
4E21 Raw Field Data Brick Transceiver Voltage 0 to 0.01 V 0.01 F001 0
4E22 Raw Field Data Brick Transceiver Current 0 to 1 mA 1 F001 0
Table B–10: MODBUS MEMORY MAP (Sheet 23 of 65)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT

Table of Contents

Related product manuals