28
WavePro™ Breaker Catalog Number Guide
WE2DAQD
1234567
Trip unit codes (See Table A)
TU function Code
none X
LS
➁
A
LSG
➂
B
LSGZ1
➂
C
LSGZ2
➂
D
LSGD
① ➂
E
LSGDZ1
① ➂
F
LSGDZ2
① ➂
G
LI
➁
J
LIG
➂
K
LIGZ1
➂
L
LIGD
① ➂
M
TU function Code
LIGDZ1
① ➂
N
LSI
➁
P
LSIG
➂
Q
LSIGX
① ➂
R
LSIGZ1
➂
S
LSIGZ2
➂
T
LSIGD
① ➂
V
LSIGDZ1
① ➂
W
LSIGDZ2
① ➂
Y
LSIX Z
①
Not UL Listed
➁
Power+ available with LI, LS or LSI only
➂ GF is 3w/4w (See Note 1 below)
Rating
Sensor Plug Code
none X
60
①
1
80 2
150 100 3
125 4
150 5
150
①
5
200 6
400 225 7
250 8
300 9
400 A
300
①
9
800 400 A
450
①
B
500 C
Rating
Sensor Plug Code
600 D
800 700 E
800 G
600
①
D
800 G
1600 1000 H
1100
①
J
1200 K
1600 M
750
①
F
800
①
G
1000 H
2000 1200 K
1500
①
L
1600 M
2000 N
Rating
Sensor Plug Code
1200 K
3200 1600 M
2400 P
3200 S
1600 M
2000 N
4000 2500 Q
3000 R
3600
①
T
4000 V
3200
①
S
5000 4000
①
V
5000
①
W
①
Rating plug value not
available on Power+
trip unit
Usage Code
AKD10/PBII/AV3 Access Equipment WE
OEM Substructure WS
Interrupting Capability/ Silver
Fuse Type Code “L” Fuse
Standard (ex. WPS) 1
High (ex. WPH) 2
Extended (ex. WPX) 3
OFLO only 4
300A Class “J” fuse A
350A Class “J” fuse B
400A Class “J” fuse C
450A Class “J” fuse D
500A Class “J” fuse E
600A Class “J” fuse F
800A Class “L” fuse G 5
1000A Class “L” fuse H 6
1200A Class “L” fuse J 7
1600A Class “L” fuse K 8
2000A Class “L” fuse L 9
2500A Silver “L” fuse M
800A “Welder” limiter N
1600A “Welder” limiter Q
2000A “Welder” limiter R
1000A “Welder” limiter Z
Frame & Sensor Code (See Note 1)
800 none A
150 B
400 C
800 D
1600 none E
800 F
1600 G
2000 none H
2000 J
3200 none K
3200 L
4000 none M
4000 N
5000 5000 R
Trip Unit type Code
none (non-automatic) X
MVT Plus A
MVT M (metering & communications) B
MVT PM (relaying, metering
& communications) C
MVT Plus (w/special GF curve)
➃
D
MVT M (w/special GF curve)
➃
E
MVT PM (w/special GF curve)
➃
F
Power +
①
G
Power + (w/GF)
① ➂
H
Power + (w/Defeatable GF)
① ➁ ➂
J
Power + (w/targets)
①
K
Power + (w/targets & GF)
① ➂
L
Power + (w/targets &
Defeatable GF)
① ➁ ➂
M
①
Power + is not available for 5000A frame breakers
➁
Not UL Listed
➂
G
F is 3w/4w (See Note 1 below)
➃
Not available on Type WS (OEM) breakers
Table A
L = Long Time (LT)
S = Short Time (ST)
I = Instantaneous (Inst)
G = Ground Fault (GF)
GD = Defeatable GF
X = Switchable ST or Inst OR
Switchable ST or Inst and GF
Z1 = Zone Selective Interlocking—GF
Z2 = Zone Selective Interlocking—
GF and ST
Note 1: If 4 wire GF is required then the "A-Disc" [character position 14] must
be selected and the 4th wire (neutral) sensor must be ordered separately.
Refer to DEP-080 Product Catalog.
Sensor = "none" for non-automatic breakers
Equipment Usage Frame Sizes & Interrupting Rating Trip Unit Type, Characteristics & Trip Rating
Fuse Link
S
on
T
Phase B
U
(not available
V
on Type WS
W
[OEM] breakers)
Y