ATTENTION The oil level must be in the
visible part of the sight glass;
damage to the compressor
is possible if overfilled or
underfilled!
3 | Areas of application
Thecompressorsarelledatthefactorywiththefollowingoiltype:
-fürR134a,R404A/R507,R407C,R407F FUCHSRenisoTritonSE55
-fürR22 FUCHSRenisoSP46
Compressorswithesteroilcharge(FUCHSRenisoTritonSE55)aremarkedwithanXinthetype
designation(e.g.HGX44e/770-4).
3.1 Refrigerants
• HFKW/HFC: R134a,R404A/R507,R407C,R407F
• (H)FCKW/(H)CFC: R22
3.2 Oil charge
INFO
For refilling, we recommend the above oil types.
Alternatives: see lubricants table, Chapter 7.5
ATTENTION Compressor operation is possible within the operating limits
showninthediagrams.Pleasenotethesignicanceofthe
shaded areas. Thresholds should not be selected as design or
continuous operation points.
- Permissible ambient temperature (-20°C) - (+60°C)
- Max. permissible discharge end temperature 140°C.
-Max.permissibleswitchingfrequency12x/h.
- A minimum running time of 3 min. steady-state condition
(continuous operation) must be achieved.
For operation with supplementary cooling:
- Use only oils with high thermal stability.
- Avoid continuous operation near the threshold.
For operation with capacity regulator:
- Continuous operation, when the capacity regulator is activated,
is not permissible and can cause damage to the compressor.
- The suction gas superheat temperature may need to be reduced
or set individually when operating near to the threshold.
- When the capacity regulator is activated, the gas velocity in the
systemcannotundercertaincircumstancesensurethatsuf-
cient oil is transported back to the compressor.
Foroperationwithfrequencyconverter:
- The maximum current and power consumption must not be
exceeded.Inthecaseofoperationabovethemainsfrequency,the
application limit can therefore be limited.
3.3 Limits of application
max.
min.
oillevel
Fig.4Fig.4
HG44e
1,6Ltr.
HG56e
1,4Ltr.
~
~
~
~