EasyManua.ls Logo

gefran ADL300 EPC v2 - Page 37

gefran ADL300 EPC v2
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
____________________ _
ADL300-EPCv2- User Guide Page 37 of 64
05.06 INPUTS
The input signals of the EPC lift application can be connected to a signal via a switch that can be used to
select from among a series of options listed in the selection list.
The selection list can be used to select from among the following options for each single input:
- Null or One
- Digital Inputs of the I/O expansion card
- Some internal signals (e.g. “Brake cont mon” ..)
- A selectable “LiftDecomp1” bit (e.g. “Lift decom1 B0”)
- A selectable “LiftDecomp2” bit (e.g. “Lift decom2 B0”)
- PAD15
In I/O configuration they are connected to digital inputs
In the CANopen configuration they are connected to the LiftDecomp connected in turn for instance via the
variable Control word 1 to a fieldbus process channel e.g. PDC FieldBus M->S1..
The variable Control word 1 can generally be connected to another fieldbus process channel or to the drive
parameter Wcomp or to PAD16.
The default configuration is shown in the table below:
Input
Description
Default source
CAM A
Cam A input
Null (*)
CAM B
Cam B input
Null (*)
Input Upper Limit
Upper limit input
Dig input 1X
Input Lower Limit
lower limit input
Dig input 2X
Input Slow Upper Limit
Slow upper limit input
Dig input 1X
Input Slow Lower Limit
Slow lower limit input
Dig input 2X
Input Contactor Feedback
Contactor feedback input
Run Cont Mon
Input Brake Feedback
Brake feedback input
Brake cont mon
Input Door Open
Door open input
Door Open Mon
Input Door Feedback
Door feedback input
Null
(*) CAM A and CAM B must always be selected Null and must always be connected to the freeze
inputs of the encoder expansion card.
This parameter allow to define how many floors is positioned the sensor before the upper floor.
This parameter allow to define how many floors is positioned the sensor before the bottom floor.
Selection of the alarm Brake out of service. The alarm function is disabled by default.
Selection list for the enabling source:
6000 Null
6002 Uno
12250 BO Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.1 11054
Cam Upper Limit ENUM 1 0 4 RW FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.2 11056
Cam Below Limit ENUM 1 1 4 RW FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.3
11252
Brake fbk A3 sel ENUM 1 1 4 RW FVS