ADL300-EPCv2- User Guide Page 59 of 64
Battery Mode
Battery Mode command
Dig input 3X
Battery Run
Battery Run command
Dig input 3X
Floor 0
Floor 0 command
Dig input 10X
Floor 1
Floor 1 command
Dig input 11X
Floor 2
Floor 2 command
Dig input 12X
Floor 3
Floor 3 command
Null
Floor 4
Floor 4 command
Null
Inputs:
Input
Description
Default source
CAM A
Cam A input
Null
CAM B
Cam B input
Null
Input Upper Limit
Upper Limit input
Dig input 1X
Input Lower Limit
Lower Limit input
Dig input 2X
Input Slow Upper Limit
Slow Upper Limit input
Dig input 1X
Input Slow Lower Limit
Slow Lower Limit input
Dig input 2X
Input Contactor Feedback
Contactor feedback input
Run Cont Mon
Input Brake Feedback
Brake feedback input
Brake cont mon
Input Door Open
Door open input
Door Open Mon
Input Door Feedback
Door feedback input
Null
7.2.1 Connection of card EXPD16R4-ADL:
This example refers to the factory settings as described above.
EXP-IO-D16R4-ADL
T3
T2
T1
Lift commands
Door open
Run contactor
Brake contactor
Drive OK
Floor 2
Floor 1
Floor 0
Realignment
Jog REV
Jog FWD
Floor call
SelfStudy
Cycle 0
Battery Mode/Run
Lower Limit
Upper Limit
Enable
RO
4O
RO
4C
RO
3O
RO
3C
RO
2O
RO
2C
RO
1O
RO
1C
DI
12
DI
11
DI
10
DI
9
DO
4
DO
3
DO
2
DO
1
DO
CM
DO
PS
DI
8
DI
7
DI
6
DI
5
DI
4
DI
3
DI
2
DI
1
EN
HW
DI
CM
OV
out
24
our
50 51 52 53 54 55 56
57
20
21 22 23
24 25 26 27 28 29
1 2 3 4 5 6 7 8 9 10 11 12
7.2.2 Connection of card EXPDE-IR1F2-ADL
Connection in case of a digital encoder, normally used in asynchronous mode.
The inputs connected to cam A and B must be allocated to fixed positions!