EasyManua.ls Logo

gefran BDI50 Series

gefran BDI50 Series
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-23
Group 13 Inspection & Maintenance functions
No. Description Range
Factory
Setting
unit Note
13-00
Drive Horsepower
Code
---- - - *3
13-01
Software Version
----
-
-
*3*4
13-02
Fault Log
(Last 3 Faults)
---- - - *3*4
13-03
Accumulated Operation
Time1 1
0~23 - hour *3
13-04
Accumulated Operation
Time1 2
0~65535 ---- day *3
13-05
Accumulated Operation
Time Mode
0:Time Under Power
1:Run Mode Time Only
0 - *3
13-06
Parameter Lock
0: Enable all Functions
1: Preset speeds 05-01~05-08 cannot
be changed
2: All Functions cannot be changed
Except for Preset speeds
05-01~05-08
3: Disable All Function
0 -
13-07
Parameter Lock Code
00000~65535
00000
-
13-08
Restore Factory
Settings
1150: Reset to factory setting.
(50Hz,220V/380V)
1160: Reset to factory setting.
(60Hz,220V/380V)
1250: Reset to factory setting.
(50Hz,230V/400V)
1260: Reset to factory setting.
(60Hz,230V/460V)
1350: Reset to factory setting.
(50Hz,220V/415V)
1360: Reset to factory setting.
(60Hz,230V/400V)
1250/1360
(*)
-
(*) Notes:
For built-in EMC filter models, the default setting of 13-08 is “1250”.
For without built-in EMC filter models, the default setting of 13-08 is “1360”