2. Technical Data
2.1 Datasheet
Type KFM05a / 180 KFM05a / 310 KFM05a / 510 KFM05a / 500L
Nominal current INetz
1,3 A 2,0 A 3,1 A 3,5 A
Rated Power PN
188 W 314 W 512 W 507 W
Motor torque MN
1,8 Nm 2,0 Nm 2,8 Nm 1,9 Nm
Rated speed nN
1000 min˙¹ 1500 min˙¹ 1750 min˙¹ 2550 min˙¹
Number of poles p
6 poles 4 poles 4 poles 4 poles
Motor frequency @ PN f
60 Hz 55 Hz 65 Hz 98 Hz
Winding resistance R
23 Ω 9 Ω 5 Ω 6 Ω
Rotor inertia torque J
11,7 kgcm² 7,2 kgcm² 15,6 kgcm² 7,2 kgcm²
Overload
Range of output frequency
Position encoder resolution
Analogue setting
Acceleration/deceleration
Functions
Positions
Interface
Handling
Software
Programming
Buffer function
Holding brake
Protection functions
Mains fuse
Safety category
Motor isolation
Connection
Ambient operating
temperature TB
Design
Type of protection
IP54 IP54 IP54 IP44 (fan)
Weight
8,3 kg 8,1 kg 11,7 kg 9,4 kg
internally 24 Vdc, optionally 230 Vac also emergency brake possible
Optionally class 3 Safety Stop DIN EN ISO 13849 (formerly EN954-1)
230 Vac ±10 % / 50 Hz ±10 %
2 x MN for 60s (200% MN respectively PN)
AIN1 and AIN2 0 -10V, 0 - 20mA, 2 -10V, 4 - 20mA, digital 24V
1000 to 0,02 Hz/s (0,05 - 2500 s)
2048 pulses per revolution ± 40 pulses linearity error
5 digital IN 24 Vdc ±20 %; 3 digital OUT 24 Vdc 50 mA short-circuit proof;
optically isolated, relay contact 30 V/1 A, optional safety relay
BG 71 according to IEC with standard-flange B14
cable bushing (metric), cable inlet or plug-in version
RS232, RS422, optional RS485, CANopen
Position control, positioning, frequency control, etc programmable
Optionally via external 24 Vdc, ±10 %, 250 mA
under- and overvoltage, overcurrent, overtemperature
Optional control panel connected for the setting of the parameters
Software for control and optimization of the parameters, control of the functions
and saving of the parameters included
externally with max 16 A, internally 5,0 A mT fuse
16 positions programmable via fieldbus, 32-Bit resolution
EN50178, EN60034-1, EN61000-6-1 - EN61000-6-4
in Flash-ROM (can be downloaded), parameters and fault memory in EEPROM
- 10°C - +40°C above with derating of performance
SIEI-AREG GmbH
Gottlieb-Daimler-Straße 17/3
74385 Pleidelsheim Germany
Fon: +49 7144 89736 0