5.4.2 Motor test on the Diagnosis Page
The window „Motor test“ can be used to start and test the KFM05A via PC without extensive wiring.
A connection between X7:14 and X7:2 and between X7:13 X7:7 enables the power amplifier,
jumper J has to be BEHIND.
The input Enable 7 in the Diagnosis Page shows “1“ and there is no fault message 6 .
The motor test-window has to activated with a tick 1 (click the field). The set frequency 4 can be
activated with the buttons 2 , the other set frequency 5 can be activated with the other buttons 3
.
SIEI-AREG GmbH
Gottlieb-Daimler-Straße 17/3
74385 Pleidelsheim Germany
Fon: +49 7144 89736 0
Art.-No.: 918 111e
Page 42 von 60