5.4 Configurator E@syDrives
1 To load a parameter file, 2 to enable or disable connection to KFM05A, 3 e.g. to set and
control the interface, 4 e.g. to activate the program „KFM LOAD“ (it is used to load another
software-version (firmware) into the KFM05a, see chapter 8.), 5 to save a changed parameter into
the EEPROM of the KFM05A, 6 RESET KFM05a, 7 view-function, 8 oscilloscope-function, 9
fault memory, 10 to print a screenshot, 11 to enlarge the window (also CTRL+F), 12 to show
the complete parameter-list, 13 HTML-pages, 14 information about common problems, 15 type
KFM05a (e.g. type with external 24 V supply), 16 display of actual warnings and faults, 17
connected or disconnected with KFM05a.
This was a short explanation. The information of Help Topics 14 also can be used to explain the
program. Every parameter has its own help-text. For this click the parameter and then press F1 or
click the active text if present (see an example of a help-text next page).
ATTENTION ! The parameters are changed in the RAM of the drive. That means after mains off
the change is gone. For a permanent saving of all parameters see 5 .