3. If the magnets do not automatically jump onto the measuring surface, press down the
knurled nuts one after the other. The magnets should now jump onto the tie bar. The
attraction force of the magnets is now optimal.
The sensor on the tie bar may only be moved fractionally.
The magnets have ground guides. Make sure that both sides of
the guide rest on the tie bar!
4. The contact force can be increased by tightening the knurled nut. (usually not necessary.)
If a magnet jumps back, the knurled nut has been tightened too much, thereby making the
spring tension too big. Loosen the knurled nut to relieve the tension of the spring.
The sensor must make proper contact and be stable.
The sensor must not move when shaken slightly.