Selection of the drive command (via terminals or digital)
- Whentheconverteriscontrolledonlyviatheterminalstrip,settheMain commands parameterto“Ter-
minals”.Beforechangethisparametersetbesurethatnovoltageissuppliedtoterminal12.
- Whenthekeypadisused,set Main commands=Digital
Saving Settings
- UseSave parameters in STARTUPmenu(orSPECIALFUNCTIONmenu).
- Userparameterssettingmustbesavedintomemory,sothatthestoredvaluesarereadthenexttimethe
deviceisswitchedon.
- Whenusingthekeypad:pressENT.
Onstandardsetting,toperformtheselftuningofcuurentregulatorduringthecommissioning,theMain com-
mandsparameterissetas“Digital”.