EasyManua.ls Logo

gefran TPD32-EV-CU series - Figure 6.12.2.1: Analog Input

gefran TPD32-EV-CU series
504 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— TPD32-EV ——————
214
+
-
6
5
Volts
Ref_3-
Ref_3+
HW
input
type
+
-
4
3
Volts
Ref_2-
Ref_2+
HW
input
type
From digital reference
setting
From digital reference
setting
+
-
2
1
Volts
Ref_1-
Ref_1+
HW
input
type
From digital reference
setting
Window comparator
F
F
F
Input 3 type
-10V ... +10V
Offset input 3
0
Scale input 3
1
Tune value inp 3
1
Select input 3
OFF
Input 2 type
-10V ... +10V
Offset input 2
0
Scale input 2
1
Tune value inp 2
1
Select input 2
OFF
Auto tune inp 3
0
Auto tune inp 2
0
Input 1 type
-10V ... +10V
Offset input 1
0
Scale input 1
1
Tune value inp 1
1
Auto tune inp 1
0
Input 1 filter
0ms
Select input 1
Ramp ref 1
Input 1 compare
0
Input 1cp error
0
Input 1cp delay
0ms
Input 1cpmatch
An in1target
An in2target
An in3target
Select input 1
Ramp ref 1
Select input 2
OFF
Select input 3
OFF
Figure 6.12.2.1: Analog input
Analog Input 1 window comparator
Thisfunctionallowstosignalthematchofaprogrammablevalueonanaloginput1.
Input 1 compare Setsthelevelforthecomparator.
Input 1 cp error DenesatolerancewindowaroundInput 1 compare.
Input 1 cp delay MilliseconddelayduringtheswitchingfromthelowtothehighlevelInput 1 cp match.
Input 1 cp match Signallingoutputofthevideocomparator.
ItcanbereadthroughaFieldBusLANordigitaloutput.
High Analog input 1valueiswithinthecomparationwindow.
Low Analog input 1valueisoutthecomparationwindow.
Window comparator
Input 1 compare
0
Input 1cperror
0
Input 1cp delay
0ms
Input 1cpmatch
Figure 6.12.2.2: Analog Input 1 window comparator