EasyManua.ls Logo

gefran TPD32-EV-CU series - Page 201

gefran TPD32-EV-CU series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— Instruction manual ——————
201
Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Open test act
Ignore(0)
Warning(1)
Disabledrive(2)
1527 - - Disabledrive Disabledrive
-
SCR test enable
OFF(0)
OpenSCRtest(1)
TestSCR(2)
Open/Shorttest(3)
1524 - - Off Off
SCR diag status
NoSCRFault
Short<SCR>
OpenW<SCR>
OpenF<SCR>
1525 NoSCRFault NoSCRFault
Open SCRX thr [%]
1528 0 100 50 50
Open test act Activitysettingfor“Open SCR”test(for“Shorted SCR”=
"Disable drive".Notcongurable).
SCR test enable EnableSCRtestwithselectionoftesttypetoberun.
OFF
Open SCR test Onceenabled,thisselection (tode-
tectopenSCRs)alwaysremainsenabledifdrivecontrolison
(Enabled+Start),
Short SCR Test Thisselection(todetectSCRsinshort
circuit)isonattherstenablingofthedrive(Enabled+Start
withgenerationofpulsestoSCRmodules).
Note:IfIPA8818=Stopmode=OFF,theSCRShorttestis
runwithouttheStartcommandon).WhentheSCRShorttest
isrun,5sofdelayisincludedbetweenexecutionoftheStart
commandandenablingofthecontrol.
Open/Short test Thisselectionsimultaneouslydetects
SCRsinshortcircuitand/oropen.Whenenabled(Enable+
Start),anySCRsinshortaredetected(requires5s),afterwhich
anyopenSCRsaredetected.
SCR diag status DisplaysstatusofmodulesafterSCRtestisrun.
No SCR Fault:NoSCRinfaultstatus.
Short <SCR>:SCRinshortcircuitdetected.Thenumberof
theSCRmoduleinshortcircuitisshownin<…>.(Forthe
2Bdrive,theSCRinshortcircuitisshown.Forthe4Bdrive,
the“pair”ofmodulesmakinguppartoftheshortedSCRare
shown.)Note:Short <5/15>;SCRno.5orno.15inshortcircuit
ingure3.
Open W <SCR>:WarningthatanSCRisopen.
Open F <SCR>:SCRopenalarm.Note:OpenF<4>:SCR
no.4openingure2.