Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Roll diameter [m]
1154 0.000 32.000
****
Line speed [%]
1160 0.00 200.00
Ref line speed [%]
1286 0.00 200.00
Diam calc Dis
ON(1)/OFF(0)
1161 0 1 ON(1) ON(1)
*
Diam inc/dec En
Enabled(1)/Disabled(0)
1205 0 1 Enabled(0) Enabled(0)
*
Wind/unwind
Unwinder(1)/Winder(0)
1187 0 1 Winder(0) Winder(0)
*
Minimum diameter [mm]
799 1 2000 100 100
Maximum diameter [m]
1153 0.000 32.000 1.000 1.000
Line spd source
1204 0 65535 0 0
Ref spd source
1284 0 65535 0 0
Line speed gain
1156 0 32767 0 0
Ref speed gain
1285 0 32767 0 0
Base omega [rpm]
1163 0 8191 1500 1500
Ref speed thr [%]
1155 0 150.00 5 5
Diam lter [ms]
1162 0 5000 100 100
Diam init lter [ms]
1206 0 5000 100 100
Diam stdy delay [ms]
1207 0 60000 0 0
Diam reset
1157 0 1 0 0
*
Diam thr [%]
1158 0 150.00 10 10
Diam reached
1159 0 1
**
Diam preset sel
1168 0 3 0 0
*
Diam preset 0 [m]
1164 0.000 32.000 0 0
Diam preset 1 [m]
1165 0.000 32.000 0 0
Diam preset 2 [m]
1166 0.000 32.000 0 0
Diam preset 3 [m]
1167 0.000 32.000 0 0
***
* Thisparametercanbesetonaprogrammabledigitalinput.
** Thisparametercanbesetonaprogrammabledigitaloutput.
*** Thisparametercanbesetonaprogrammableanaloginput.
****Thisparametercanbesetonaprogrammableanalogoutput.
Theinputsreceivedbythediametercalculatoraretheangularspeedofthecontrolledmotorandthelinespeed.
Thelattercanbemeasuredthroughananaloginputoranencoder.
Thevalueofthecalculateddiametercanbesenttoananalogoutput;viaadigitaloutputitisalsopossibleto
statetheovercomingofaprogrammablethreshold.
Itispossibletoselectfourvaluesofthestartingdiameters;onevaluecanderivefromananaloginput.
Roll diameter Monitorofthecalculateddiameterin[m].
Line speed Monitorofthelinespeedin[%].
Ref line speed Referencemonitorforthelinespeedin[%].
Diam calc Dis Disablingofthediametercalculation(seealsopar.Ref speed thr).Incasesuchfunc-
tionistemporarilydisabledduringthefunctioningperiod,thesystemstoresthelast
calculatedvalue.
Diam inc/dec En Ifenabledandifwinder,thecalculateddiametercanneverdecrease;ifunwinderthe
calculateddiametercanneverincrease.Itisusedtoimprovethesystemstability.
Wind/unwind Winder/unwinderselection.Iftheselectioniscarriedoutviaadigitalinput:0V=winder,
+24V=unwinder.
Minimum diameter Valueoftheminimumdiameterin[mm].

Table of Contents