EasyManuals Logo

gefran TPD32-EV-CU series User Manual

gefran TPD32-EV-CU series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #459 background imageLoading...
Page #459 background image
—————— Instruction manual ——————
459
Parameter No. Format
Value Access via
min max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
FUNCTIONS \ Speed draw
Speedratio
1017 I16 0 +32767 +10000 +10000
ü
R/W IA R/W
Speeddrawout(d)
1018 I16 -32768 +32767 - -
ü
R QA R/W
Speeddrawout(%)
1019 Float -200.0 +200.0 - -
ü
R - -
FUNCTIONS \ Overload contr
Enableoverload
Enabled
Disabled
309 I16 0 1 Enabled Disabled
ü
R/Z
1
0
- -
Overloadmode
Currlimited
Currnotlimited
I2tMotor
I2tDrive
I2tMotor&Drv
318 U16 0 4 I
2
tMotor Curr
limited
ü
R/W
0
1
2
3
4
- -
Overloadcurrent[%]
312 U16 P313 200 150 100
ü
R/W - -
Basecurrent[%]
313 U16 0 P312
<100
100 80
ü
R/W - -
Overloadtime[s]
310 U16 0 65535 60 30
ü
R/W - -
Ventil.Type
SERVO
AUTO
914 U16 0 1 Servo Servo
0
1
ü
R/Z - -
Deratingfactor[%]
915 U16 0 100 50 50
ü
R/Z - -
Motorovrldpreal.
1289 U16 0 1 - -
ü
R - -
MotorI2taccum
655 Float 0,00 100,00 - -
ü
R - -
Driveovrldpreal.
1438 U16 0 1 - -
ü
R - -
DriveI2taccum
1439 FLOAT 0,00 100,00 - -
ü
R - -
Pausetime[s]
311 U16 0 65535 540 300
ü
R/W - -
Overldavailable
Overloadnotpossible
Overloadpossible
406 U16 0 1 - - - R
0
1
QD
L
H
R
0
1
Overloadstate
Currentlimitvalue
Current>limitvalue
407 U16 0 1 - - - R
0
1
QD
L
H
R
0
1
FUNCTIONS \ Stop control
Stopmode
OFF
Stop&speed0
Faststp&spd0
Fst/stp&spd0
626 U16 0 3 Stop&
Speed0
Stop&
Speed0
ü
R/Z
0
1
2
3
- -
Spd0tripdelay[ms]
627 U16 0 40000 0 0
ü
R/W - -
Tripcontdelay[ms]
628 U16 0 40000 0 0
ü
R/W - -
Jogstopcontrol
OFF
ON
630 U16 0 1 OFF OFF
ü
R/Z
0
1
- -
FUNCTIONS \Brake control
EnableTorquepr
1295 I16 0 1 Disabled Disabled
ü
R/W - -
Closingspeed[rpm]
1262 U16 0 200 30 30
ü
R/W - -
Torquedelay[ms]
1293 I16 0 30000 3000 3000
ü
R/W - -
Torqueproving[%]
1294 I16 0 200 75 75
ü
R/W - -
Actuatordelay[ms]
1266 U16 0 30000 1000 1000
ü
R/W - -
FUNCTIONS \ I/n curve (Taper curr lim)
I/ncurve
Enabled
Disabled
750 U16 0 1 0 0
ü
R/Z
1
0
- -
I/nlim0[%]
751 U16 0 200 0 0
ü
R/Z - -
I/nlim1[%]
752 U16 0 200 0 0
ü
R/Z - -
I/nlim2[%]
753 U16 0 200 0 0
ü
R/Z - -
I/nlim3[%]
754 U16 0 200 0 0
ü
R/Z - -
I/nlim4[%]
755 U16 0 200 0 0
ü
R/Z - -
I/nspeed[rpm]
756 U16 0 P162 0 0
ü
R/Z - -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran TPD32-EV-CU series and is the answer not in the manual?

gefran TPD32-EV-CU series Specifications

General IconGeneral
Brandgefran
ModelTPD32-EV-CU series
CategoryDC Drives
LanguageEnglish

Related product manuals