—————— Instruction manual ——————
499
OPTIONS \ OPTION 1 \ PDC CONFIG \ PDC INPUTS
Parameter No. Format
Value Access via
min max Factory Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Pdcin0...5
Field current
1472
...
1475
U16 0 65535 Unused
ü
R/Z
8391
- -
Differentfactorydefault:
Parameter No. Format
Value Access via
min max Factory Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
SPEED REGULAT
Enablespdreg
Enable
Disable
242 I16 0 1
Disabled
ü
R/W
1
0
- -
START UP \ Speed feedback
Speedfbksel
Encoder1
Encoder2
Tacho
Armature
414 U16 0 3 Armature
ü
R/Z
0
1
2
3
- R
CURRENT REGULAT
CD curr thr
838 Int16 0 200 100
ü
R/W - -
CD factor P
839 Float 0.001 100/
DCCurr
P(P847)
0.3
ü
R/W - -
InSSC Error menu, the parameter888replacesparameter409 of standard version TPD32-EV:
CONFIGURATION \ Prog alarms \ SSC Error
Threshold
409 U16 0 250 50
ü
R/W - -
Holdofftime[ms]
888 U16 0 500 80
ü
R/W - -
EliminatedselectionsfromSelect output 1...4parameters:
I/O CONFIG \ ANALOG OUTPUTS \ ANALOG OUTPUT 1 ... 4
[27]Fluxcurrent
[35]Fluxreference
[79]Outvltlevel
[80]Fluxcurrentmax
EliminatedselectionsfromSelect input 1...3parameters:
I/O CONFIG \ ANALOG INPUTS \ ANALOG INPUT 1 ... 3
[25]Fluxcurrentmax
[26]Outvltlevel

Table of Contents