60 917001/CP0905
5. Refill the hydraulic oil reservoir with oil. Refer to the Lubrication chart
(page 52).
6. Spin off the old hydraulic filter element and spin on the new filter element.
Changing Hydraulic Oil
The hydraulic oil must be replaced if it becomes contaminated, after major
repairs and after 1000 hours or one year of use.
1. Install a catch pan of sufficient capacity under the oil reservoir, see page 51.
2. Remove the drain plug located on the bottom front of the oil reservoir, behind
the right rear tire. Allow the oil to drain.
3. Reinstall the drain plug.
4. Change the oil filter.
5. Refill the reservoir. Refer to the Lubrication topic (page 51).
6. Start the engine and operate the hydraulic controls.
7. Stop the engine and check for leaks at the filter and reservoir drain plug.
8. Check the fluid level and add fluid if needed.
Bucket Cutting Edge
The bucket cutting edge should be replaced when it is worn to within 1 in.
(25 mm) of the bucket body.
Alternator/Fan Belt
Refer to the separate engine manual for setting proper belt tension. If the belt is
worn, cracked or otherwise deteriorated, replace the belt following the procedure
in the engine manual.
Wheel Nuts
Wheel nut torque must be checked before initial operation and every two hours
thereafter until the wheel mounting hardware torque remains at 180 ft-lbs
(244 N·m). When wheels are removed and reinstalled this procedure must be
repeated.
Lift Arm Pivots
The All-Tach pivot should be torqued periodically to 240 ft-lbs (325 N·m). Refer
to the Maintenance Interval chart (page 75).