Why is the entire electrical system not functioning on my Gehl SL4635?
- HhrogersAug 1, 2025
If the entire electrical system on your Gehl Compact Loader isn't working, there are several potential causes. First, ensure the battery disconnect switch is turned to the “On” position. Check the 20 ampere breakers; if they are tripped, consult the wiring diagram to identify and fix any circuit issues like pinched wires or faulty connections before resetting the breaker. Inspect the main wiring harness connectors at the rear of the ROPS to ensure they are properly plugged in. Also, check the battery terminals and cables, cleaning and retightening them if they are loose or corroded. Finally, test the battery itself and replace it if necessary.