CHAPTER 9
TROUBLESHOOTING
This Troubleshooting Guide lists potential problems, as
well as possible causes and remedies, for Gehl skid
loaders.
When a problem occurs, don’t overlook simple causes.
A malfunction could be caused by something as simple
as an empty fuel tank. After a mechanical failure has
been corrected, be sure to locate the cause of the
problem.
IMPORTANT: DO NOT attempt to service or
repair major components, unless authorized to do
so by your Gehl dealer. Any unauthorized repair
will void the warranty.
907808/CP0300 54 PRINTED IN USA
Electrical System
Problem Possible Cause Remedy
Entire electrical
system does not
function.
Battery disconnect switch is “Off”
20 ampere breakers are tripped.
Main wiring harness connectors at rear
of ROPS not properly plugged in.
Battery terminals or cables are loose or
corroded.
Battery is faulty.
Turn battery disconnect switch to “On”.
Consult wiring diagram, check circuit and
locate trouble (i.e., pinched wires, faulty
connections, etc.) before resetting
breaker.
Check main harness connectors.
Clean battery terminals and cables and
retighten them.
Test battery and replace as needed.
No instrument panel
lamps with keyswitch
turned to “ON.”
20 ampere breaker tripped.
Battery terminals or cables are loose or
corroded.
Consult wiring diagram, check circuit and
locate trouble before resetting breaker.
Clean battery terminals and cables and
retighten them.
No glow indicator lamp
with key switch turned
to “ON.”
Ambient temperature above 32° F (0°C)
Bulb is burned out.
Faulty glow module.
Proceed with starting engine.
Replace bulb.
Contact your Gehl dealer for assistance.
Seat belt buzzer
indicator not sounding
when key turned to
“ON”, indicator lamps
work properly.
Buzzer is disconnected.
Faulty buzzer.
Reconnect wires to buzzer.
Replace buzzer.
Fuel gauge does not
work.
Faulty fuel gauge sender.
Faulty fuel gauge.
Loose wiring/terminal connections.
Replace fuel gauge sender.
Replace fuel gauge.
Verify wiring connections.

Related product manuals