Owner’s Manual for Portable Generator 13
Transporting/Tipping of the Unit
Do not store or transport the unit at an angle
greater than 15 degrees.
Starting Pull Start Engines
IMPORTANT NOTE: Electronic system
requires 10V minimum at battery connec-
tions for pull starting. The engine will not
start unless the battery connections have
the required voltage for the electronics and
fuel pump. If the fault indicator light
flashes rapidly with key in RUN position,
the generator will not start. Charge battery
prior to starting.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. Rotate key to RUN. The RUN light will stay
on. See Figure 3-2.
.
Figure 3-2. Rotate Key
4. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
Do not overload generator or individual panel
receptacles. These outlets are overload pro-
tected with push-to-reset circuit breakers. If
amperage rating of any circuit breaker is
exceeded, that breaker opens and electrical
output to that receptacle is lost. Read Know
Generator Limits carefully.
Starting Electric Start Engines
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. Rotate key to RUN, wait 1 second. Rotate
key to START until engine starts. See Fig-
ure 3-2.
NOTE: The key will automatically switch to
RUN and the fault light will turn off.
Generator Shut Down
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Turn key to OFF.
Low Oil Pressure Shutdown
System
The engine is equipped with a low oil pressure
sensor that shuts down the engine automati-
cally when the oil pressure drops below speci-
fications. The engine will not run until the oil
has been filled to the proper level.
If the engine shuts down and there is sufficient
fuel, check engine oil level.
Radio 50 to 200
*Refrigerator 700
Slow Cooker 200
*Submersible Pump (1-1/2 HP) 2800
*Submersible Pump (1 HP) 2000
*Submersible Pump (1/2 HP) 1500
*Sump Pump 800 to 1050
*Table Saw (10") 1750 to 2000
Television 200 to 500
Toaster 1000 to 1650
Weed Trimmer 500
* Allow 3 times the listed watts for starting these
devices.
(000183)
WARNING
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
005809
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.

Table of Contents

Other manuals for Generac Power Systems XT8000EFI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems XT8000EFI and is the answer not in the manual?

Generac Power Systems XT8000EFI Specifications

General IconGeneral
BrandGenerac Power Systems
ModelXT8000EFI
CategoryPortable Generator
LanguageEnglish

Related product manuals