Owner’s Manual for Portable Generator 7
There are 3 levels of failures:
1. Level 1 will flash and the generator will
run. There may be a slight impact on per-
formance.
2. Level 2 will flash and the generator will
shut down if multiple errors are detected.
3. Level 3 will shut down the generator.
Fault
Code
Fault Code Fault Flash (Seconds)
2 TPS Failure On-0.25s, Off-0.5s, On-0.25s
3 Cylinder Temp. Failure On-0.25s, Off-0.5s Repeat 2X
4 Temp. Failure On-0.25s, Off-0.5s Repeat 3X
5 System Voltage Low On-0.25s, Off-0.5s Repeat 4X
6 System Voltage High On-0.25s, Off-0.5s Repeat 5X
7 Cylinder High Temp. On-0.25s, Off-0.5s Repeat 6X
8 Barometric Pressure Sensor
Failure
On-0.25s, Off-0.5s Repeat 7X
9 Oil Pressure Anomaly On-0.25s, Off-0.5s Repeat 8X
11 Fuel Injector Failure On-1.2s, Off-0.5s, On-0.25s
13 Fuel Pump Failure On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 2X
15 Ignition Failure On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 4X
17 ECU Internal Failure On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 6X
18 Crankshaft Position Sensor
Failure
On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 7X
19 ECU Reset On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 8X
22 Engine Overspeed Failure (On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
Repeat 1X
24 Load Stability Sensor Failure (On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
Repeat 3X
27 Stepper Motor Stuck (On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
Repeat 6X
28 Engine Starting Failure (On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
Repeat 7X
Low Battery On-0.2s, Off-0.2s