Mug Sensor - Current: This menu gives the engineer an indication as to the
efficiency of the SureVend™ sensor. The range for correct operation is a
numerical value between 51 - 255.
1. Highlight Mug Sensor - Current from the
Switches & Sensors menu and press the ↵
(Edit) key. The LCD will display the screen
as shown opposite. The numerical value
shown indicates the current mug sensor
value.
2. The Mug Sensor value can be any number between 0 and 255 and
represents the current value read from the sensor. The engineer can test
the mug sensor by blocking the SureVend™ sensors located in the drink
dispense area. The value displayed in the status line will drop as the
sensors are blocked.
Mug Sensor - Average: This menu gives the engineer an indication as to
overall efficiency of the SureVend™ sensor.
1. Highlight Mug Sensor - Average from the
Switches & Sensors menu and press the ↵
(Edit) key. The LCD will display the screen
as shown. The value displayed represents
the average sensor calibration value.
4.3.5 Test Vend Without Cups
This menu allows the engineer to test vend a selection without dropping a cup.
N.B. Ensure that a suitable container is placed under the dispense position to
receive the vend.
1. Highlight Test Vend Without Cups in the
main Test menu and press the ↵ (Edit)
key. The LCD will display the screen as
shown opposite. Make a selection using
the drink selection keypad and press the
START/? button. The machine will
dispense the selection without dropping a cup.
2. Press the X (Exit) key to return to the main test menu screen.
Technical Manual
30