3. Soluble Compensation: Enter the Selection Timers menu and access
the Hot Water sub menu. Check and note the water timer setting (default
160ml). Return the machine to standby mode and vend a hot water
selection. Carefully measure the amount of water dispensed. If the
dispensed amount is less or more than 160ml, return to the Water
Compensation menu as described above and enter the Soluble
Compensation sub menu - default value 115. Enter a value higher (e.g. 120)
or lower (e.g. 110), return to standby, vend a second hot water selection
and measure the amount of water dispensed. Continue increasing/
decreasing the water compensation amount until a measured value of
160ml is dispensed.
4. Freshbrew Compensation: Enter the Selection Timers menu and access
the Freshbrew Coffee sub menu. Check and note the water timer setting
(default 80ml plus 40ml for sugar and 40ml for milk). Return the machine
to standby mode and vend a black freshbrew coffee (no sugar) selection.
Carefully measure the amount of water dispensed. If the dispensed amount
is less or more than 160ml, return to the Water Compensation menu as
described above and enter the Freshbrew Compensation sub menu -
default value 115. Enter a value higher (e.g. 120) or lower (e.g. 110), return
to standby, vend a second black freshbrew coffee selection and measure
the amount of water dispensed. Continue increasing/decreasing the water
compensation amount until a measured value of 160ml is dispensed.
5. Espresso Compensation: Enter the Selection Timers menu and access
the Espresso sub menu. Check and note the water timer setting (default
45 ml plus 15 ml for sugar). Return the machine to standby mode and
vend an espresso (no sugar) selection. Carefully measure the amount of
water dispensed. If the dispensed amount is less or more than 60 ml,
return to the Water Compensation menu as described above and enter
the Esp Compensation sub menu - default value 160. Enter a value higher
(e.g. 165) or lower (e.g. 155), return to standby, vend a second espresso
selection and measure the amount of water dispensed. Continue
increasing/decreasing the water compensation amount until a measured
value of 60ml is dispensed.
Technical Manual
41

Table of Contents

Other manuals for Genesis Instant

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Genesis Instant and is the answer not in the manual?

Genesis Instant Specifications

General IconGeneral
BrandGenesis
ModelInstant
CategoryVending machines
LanguageEnglish