Operator's Manual Third Edition • First Printing
Maintenance
60 ZX-135/70 Part No. 1272823GT
Check the Engine Coolant Level –
Liquid Cooled Models
Maintaining the engine coolant at the proper level
is essential to engine service life. Improper coolant
level will affect the engine’s cooling capability and
damage engine components. Daily checks will
allow the inspector to identify changes in coolant
level that might indicate cooling system problems.
1 Check the fluid level in the coolant recovery
tank. Add fluid as needed.
Result: The fluid level should be in the
NORMAL range.
Bodily Injury Hazard. Fluids in the radiator are
under pressure and extremely hot. Use caution
when removing cap and adding fluids.
Check the Batteries
Proper battery condition is essential to good
machine performance and operational safety.
Improper fluid levels or damaged cables and
connections can result in component damage and
hazardous conditions.
Electrocution hazard. Contact with hot or live
circuits may result in death or serious injury.
Remove all rings, watches and other jewelry.
Bodily injury hazard. Batteries contain acid.
Avoid spilling or contacting battery acid.
Neutralize battery acid spills with baking soda
and water.
1 Put on protective clothing and eye wear.
2 Be sure that the battery cable connections are
tight and free of corrosion.
3 Be sure that the battery hold-down brackets
are in place and secure.
Note: Adding terminal protectors and a corrosion
preventative sealant will help eliminate the
corrosion on the battery terminals and cables.
Scheduled Maintenance
Maintenance performed quarterly, annually and
every two years must be completed by a person
trained and qualified to perform maintenance on
this machine according to the procedures found in
the service manual for this machine.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before they are put back into service.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Genie ZX-135/70 with Jib-Extend and is the answer not in the manual?

Genie ZX-135/70 with Jib-Extend Specifications

General IconGeneral
Turntable Rotation360° continuous
Platform Rotation160°
Gradeability45%
Maximum Platform Height135 ft
Engine Power74 hp
Fuel TypeDiesel
Stowed Height (ft)10 ft
Max Working Height141 ft
Platform Height135 ft
Max Horizontal Reach70 ft
Platform Capacity600 lbs
Machine Width8 ft 2 in
Stowed Height10 ft
Drive Speed - Stowed3.5 km/h
Jib Length12 ft
Horizontal Reach70 ft
Platform Capacity (lbs)600 lbs
Drive Speed3.5 km/h
Stowed Length43 ft 2 in / 13.16 m
Stowed Width8 ft 2 in