3.3. Environmental conditions
3.3.1. Temperature
Operating temperature range is +5°C to +40°C
3.3.2. Humidity
Relative Humidity (RH) <50% at +40°C, non-condensing
3.3.3. Altitude
To a maximum of 1000m above mean sea level
3.3.4. Contaminants
Filters are provided to protect the
e
-Brick against moisture and dust ingress to
IP32 in accordance with EN60529.
3.3.5. Vibration, shock and bump
It is recommended that the
e
-Brick should be installed in a location where
vibration is minimized and there is minimal risk of shock or bump forces. If vibration
is excessive for a given installation, anti-shock mountings may be required.
3.3.6. Electromagnetic compatibility
The
e
-Brick is designed to comply with the relevant EMC legislation for industrial
installations:
EN61000-6-4:2007 EMC – Emission Standard for industrial environments
EN61000-6-2:2005 EMC – Immunity for industrial environments
GEW UV
e